Extron electronic MLC 62 IR D manual Command and Response Table for SIS Commands, Button Selection

Page 64

Command and Response Table for SIS Commands

Command

ASCII Command

Response

Additional Description

(Host to Unit)

(Unit to Host)

 

 

Button Selection

 

 

 

Trigger a button

E B* X! BTNO}

BtnoB* X! ]

Execute the commands

 

 

 

programmed to button X!. (This

 

 

 

command produces the same

 

 

 

results as pressing button X! on

 

 

 

the front panel).

 

 

 

X! = 01, 02, 03, 04, 05, 06, 07,

 

 

 

08, 09, or 10.

NOTES: When you press a dual-sized button, such as the Input buttons on the MLC 64, different

 

numbers appear on your screen depending on which side of the button is pressed. For

 

example, if you press the left side of the PC button on an MLC 64, the host response is

 

BtnoB*3, while pressing the right side of that button receives the response BtnoB*4. The

 

entire button lights, however, and the same command is issued regardless of which side is

 

pressed.

 

 

 

Use the MLC 60 Series Windows-based configuration software to configure the buttons

 

with commands.

 

 

Example

E B*5BTNO }

BtnoB*05 ]

Perform commands assigned to

 

 

 

button 5.

Discrete Audio Volume Adjustment on Devices with Volume Tables (MLC 62 RS models only)

Set volume level14

X( V

Vol X( ]

Set volume table level to X(. X(

 

 

 

can be up to 3 digits; leading

 

 

 

zeros are optional.

NOTE: Only positive values are allowed. Volume table levels start with 0 (zero). Setting a discrete volume level

that is outside of the volume table range results in an E13 error response.

Increment volume level

+V

Vol X( ]

Increase the volume by one

 

 

 

volume table increment.

 

 

 

X( = current volume level.

Decrement volume level

–V

Vol X( ]

Decrease the volume by one

 

 

 

volume table increment.

View current volume level

V

X( ]

Display the current volume level.

Increase and Decrease Audio Volume on Devices without Volume Tables (MLC 62 models only)

NOTE: Attempts to enter an X( V (Set volume level) command to set a discrete volume level on a device whose driver does not include a volume table result in an E14 error response.

Increment volume level

+V

Vol+

Increase the volume level by one

 

 

 

step.

Decrement volume level

–V

Vol–

Decrease the volume level by

 

 

 

one step.

View volume level

V

---

 

MLC 60 Series MediaLink Controllers • SIS Control

58

Image 64
Contents MLC 60 Series Safety Instructions English FCC Class a Notice Conventions Used in this Guide Software CommandsNotifications Contents MLC 60 Series MediaLink Controllers Contents About the MLC 60 Series MediaLink Controllers About This GuideMLC Models MLC 62 RS EU Features Faceplate alternativesVolume adjustment MLC Configuration Software Device Drivers Application DiagramsMLC 62 IR D Controlling a Projector System Requirements ExtronFeatures Installation, Operation Installation OverviewFront and Left Side Panels MLC D Front PanelsMLC 62 D front panels MLC 64 RS VC D front panelMLC 62 RS EU and MLC 62 RS MK Front and Side Panels Controls behind the wallplateFront panel features Buttons Rear Panel Features MLC 60 Series D Models Rear PanelsPort B IR/S Rear Panel Features on MLC 62 RS EU and MLC 62 RS MK Only MLC 64 RS VC D Volume Control Module Rear PanelRemoving and Replacing the Faceplates InstallationRemoving and replacing an MLC D faceplate Removing the Faceplate MLC 60 Series D Models Replacing the MLC 64 volume control knob Removing the MLC 64 Volume Control Module Faceplate Removing and replacing the MLC 62 RS EU and MK faceplatesReplacing Buttons Replacing the Faceplate MLC 62 RS EUConnecting to Port a RS-232 Wiring for RS-232 Control RS Models OnlyConnecting to Port B IR/S Wiring for IR Control Wiring the Relays Port RS Models OnlyWiring the Digital Input Port RS Models Only MLCWiring the Host/Config Port Connecting a Two-position Switch to the Digital Input PortWiring the Volume Control Module MLC 64 RS VC D Only Connecting Power to the MLCConfiguring the MLC via the USB Port Connecting a Power Supply to an MLCUSB Port Connection for MLC 62 RS EU and MLC 62 RS MK Page IR Learning IR Learning on an MLC D ModelMounting an MLC 62 D Mounting the MLC 60 Series ControllersMounting an MLC 62 D to an electrical junction box Mounting an MLC 62 D to a Decora Mounting Bracket Mounting an MLC 62 D to a Decora Mounting BracketMounting the MLC 64 RS VC D Mounting an MLC 64 RS VC D to an electrical junction boxMounting an MLC 64 RS VC D to a Decora Mounting Bracket Mounting an MLC 64 D to a Two-gang Decora Mounting BracketMounting the MLC 62 RS EU and the MLC 62 RS MK Mounting the MLC 62 RS EU to an Electrical BoxMounting the MLC EU in a Raceway Using Spacers Optional Mounting the MLC 62 RS MK to an External Electrical BoxMounting the MLC 62 RS EU Using a Spacer Accessing Covered Panel Features After Mounting Accessing the Covered MLC D Front Panel FeaturesLocking Using the Front Panel Buttons Front Panel Security LockoutResetting to the default configuration Resetting the MLC Using the Reset ButtonResetting to the factory firmware defaults About the MLC Configuration Program Computer System RequirementsDownloading and Installing the Software from the Web Installing the Configuration SoftwareInstalling the Software from the DVD Starting the Configuration Software Start Options WindowAdd Device Window with Select Model Menu Displayed Accessing the Help File Downloading Drivers Using the Configuration Program Obtaining Device DriversDriver Subscription Window Driver Subscription Download Screen Downloading Drivers from the Disc Drivers Tab and Button on the Software DVD Opening ScreenMLC 60 Device Drivers Page on DVD To download the driver packageTo download a single driver Saving a Single Driver to the ComputerDownloading Drivers from the Web Entering MLC 60 Series Driver Search Criteria Host-to-Controller Communications Error ResponsesController-initiated Messages Using the Command and Response Table Symbol DefinitionsX2# X2% MLC 60 Series MediaLink Controllers SIS Control Command Ascii Command Response Additional Description Command and Response Table for SIS CommandsButton Selection Front Panel Lockout Executive Mode Relay Functions RS models onlyDigital Input Data Port RS models only Device NamingReset/Erase Information RequestsQuery LED status = Button row 4, second LED = Button row 4, third LEDSpecifications MLC 62 Series SpecificationsControl digital input monitoring port RS models GeneralMLC 62 RS EU EMI/EMC MLC 64 RS VC D Specifications MLC 64 RS D Warranty Included Parts Replacement Part Number Part Numbers and AccessoriesIncluded Parts MLC 62 RS EU MLC 64 RS VC D Accessories Accessories Part Number For ModelUSA, Canada, South America Japan Central America Europe, Africa, and the Middle China EastAsia Middle East Europe