Extron electronic MLC 62 IR D manual Wiring for IR Control, Wiring the Relays Port RS Models Only

Page 29

Wiring for IR Control

To control devices via infrared (IR) commands from the MLC, connect one or two IR emitters to the IR/S port (RS models) or the IR port (IR model). The IR and IR/S ports provide unidirectional IR signal output to control a display, projector, switcher, or other device such as a VCR or DVD player.

You can connect one or two single IR emitters or one dual IR emitter to the IR or IR/S port

to control one or two devices. Because the MLC captive screw plugs have small openings that accept just one wire per pole, to connect two IR emitters to the MLC, insert one ground wire (black) and one IR signal wire (black with a white stripe) in the MLC 62 IR or

IR/S port, then connect the IR emitters to those wires, as shown below.

VCR

 

 

 

IR Signal

(+)

 

(–)

(–)

(–)

Ground

 

 

 

 

 

 

(+)

 

(+)

IR Signal

 

 

Ground

(+)

 

(–)

 

 

 

One Dual IR Emitter

Two Single IR Emitters

DVD Player

 

Legend

(–)Black Wire

(+) Black Wire with White Stripe

Figure 23. IR Emitters for the MLC 60 Series

For IR control, there can be a maximum of 50 feet (15 m) between the IR or IR/S port and the IR emitters.

Example: The illustration on the next page shows a single IR emitter connected to the IR/S port of an MLC 62 RS D or an MLC 64 RS D.

1

GROUND Tx/IR

GROUND

Tx

GROUND +12 VDC

PWR PORT A PORT B R 12V RS-232 IR/ S 0.4 A MAX

Ground ( )

IR Signal

50'

(15 m)

IR Emitter

MLC RS D Rear Panel

Figure 24. Connecting an IR Emitter to the IR/S Port of an MLC RS D

Wiring the Relays Port (RS Models Only)

Connect one or two devices such as room lights, a projector lift, or a motorized screen (shown in the example on the next page) to the Relays port. This port accommodates two relay connections.

To connect a device to one of the relay ports:

1.Connect the ground wire of the device to pin 3 of the provided 3-pole captive screw connector.

2.Connect the signal wire of the device to pin 1 or 2 of the 3-pole connector.

3.Plug the 3-pole connector into the MLC 3-pole captive screw Relays port.

Example: In the illustration on the next page, a low-voltage controller connected to a motorized screen has been wired to pins 2 and 3 of the provided 3-pole captive screw plug. When this connector is plugged into the rear panel Relays port, the device will be connected to the MLC relay port 2 (pins 2 and Common of the MLC 3-pole Relays connector).

MLC 60 Series MediaLink Controllers • Features, Installation, and Operation

23

Image 29
Contents MLC 60 Series Safety Instructions English FCC Class a Notice Notifications Software CommandsConventions Used in this Guide Contents MLC 60 Series MediaLink Controllers Contents MLC Models About This GuideAbout the MLC 60 Series MediaLink Controllers MLC 62 RS EU Faceplate alternatives FeaturesVolume adjustment Application Diagrams MLC Configuration Software Device DriversMLC 62 IR D Controlling a Projector Extron System RequirementsInstallation Overview Features Installation, OperationMLC D Front Panels Front and Left Side PanelsMLC 64 RS VC D front panel MLC 62 D front panelsControls behind the wallplate MLC 62 RS EU and MLC 62 RS MK Front and Side PanelsFront panel features Buttons MLC 60 Series D Models Rear Panels Rear Panel FeaturesPort B IR/S MLC 64 RS VC D Volume Control Module Rear Panel Rear Panel Features on MLC 62 RS EU and MLC 62 RS MK OnlyRemoving and replacing an MLC D faceplate InstallationRemoving and Replacing the Faceplates Removing the Faceplate MLC 60 Series D Models Replacing the MLC 64 volume control knob Removing and replacing the MLC 62 RS EU and MK faceplates Removing the MLC 64 Volume Control Module FaceplateReplacing the Faceplate MLC 62 RS EU Replacing ButtonsConnecting to Port B IR/S Wiring for RS-232 Control RS Models OnlyConnecting to Port a RS-232 Wiring the Relays Port RS Models Only Wiring for IR ControlMLC Wiring the Digital Input Port RS Models OnlyConnecting a Two-position Switch to the Digital Input Port Wiring the Host/Config PortConnecting Power to the MLC Wiring the Volume Control Module MLC 64 RS VC D OnlyConnecting a Power Supply to an MLC Configuring the MLC via the USB PortUSB Port Connection for MLC 62 RS EU and MLC 62 RS MK Page IR Learning on an MLC D Model IR LearningMounting an MLC 62 D to an electrical junction box Mounting the MLC 60 Series ControllersMounting an MLC 62 D Mounting an MLC 62 D to a Decora Mounting Bracket Mounting an MLC 62 D to a Decora Mounting BracketMounting an MLC 64 RS VC D to an electrical junction box Mounting the MLC 64 RS VC DMounting an MLC 64 D to a Two-gang Decora Mounting Bracket Mounting an MLC 64 RS VC D to a Decora Mounting BracketMounting the MLC 62 RS EU to an Electrical Box Mounting the MLC 62 RS EU and the MLC 62 RS MKMounting the MLC 62 RS MK to an External Electrical Box Mounting the MLC EU in a Raceway Using Spacers OptionalMounting the MLC 62 RS EU Using a Spacer Accessing the Covered MLC D Front Panel Features Accessing Covered Panel Features After MountingFront Panel Security Lockout Locking Using the Front Panel ButtonsResetting to the factory firmware defaults Resetting the MLC Using the Reset ButtonResetting to the default configuration Computer System Requirements About the MLC Configuration ProgramInstalling the Software from the DVD Installing the Configuration SoftwareDownloading and Installing the Software from the Web Start Options Window Starting the Configuration SoftwareAdd Device Window with Select Model Menu Displayed Accessing the Help File Obtaining Device Drivers Downloading Drivers Using the Configuration ProgramDriver Subscription Window Driver Subscription Download Screen Drivers Tab and Button on the Software DVD Opening Screen Downloading Drivers from the DiscTo download the driver package MLC 60 Device Drivers Page on DVDSaving a Single Driver to the Computer To download a single driverDownloading Drivers from the Web Entering MLC 60 Series Driver Search Criteria Controller-initiated Messages Error ResponsesHost-to-Controller Communications Symbol Definitions Using the Command and Response TableX2# X2% MLC 60 Series MediaLink Controllers SIS Control Button Selection Command and Response Table for SIS CommandsCommand Ascii Command Response Additional Description Relay Functions RS models only Front Panel Lockout Executive ModeDigital Input Data Port RS models only Device NamingInformation Requests Reset/Erase= Button row 4, second LED = Button row 4, third LED Query LED statusMLC 62 Series Specifications SpecificationsGeneral Control digital input monitoring port RS modelsMLC 62 RS EU EMI/EMC MLC 64 RS VC D Specifications MLC 64 RS D Warranty Included Parts Part Numbers and AccessoriesIncluded Parts Replacement Part Number MLC 62 RS EU MLC 64 RS VC D Accessories Part Number For Model AccessoriesEurope, Africa, and the Middle China East USA, Canada, South America Japan Central AmericaAsia Middle East Europe