3. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely affect performance and warranty coverage. For more information, contact Hoshizaki Technical Support at
a)Default Dip Switch Settings
The dip switches are factory set to the following positions:
S4 Dip Switch
S4 Dip Switch No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
|
|
|
|
|
|
|
|
|
|
|
ON | OFF | ON | OFF | ON | ON | OFF | OFF | OFF | ON | |
|
|
|
|
|
|
|
|
|
|
|
ON | OFF | ON | OFF | ON | ON | OFF | OFF | OFF | ON | |
|
|
|
|
|
|
|
|
|
|
|
ON | OFF | ON | OFF | ON | ON | OFF | OFF | OFF | ON |
S5 Dip Switch
("G" Control Board: Auxiliary Code U‑1 and Later)
S5 Dip Switch No. | 1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
OFF | OFF | OFF | OFF | OFF | |
|
|
|
|
|
|
OFF | OFF | OFF | OFF | OFF | |
|
|
|
|
|
|
OFF | OFF | OFF | OFF | OFF | |
|
|
|
|
|
|
Freeze Timer (9 & 10)
Factory Use (8)
Bin Control Selector (7) "E" Control Board
Harvest Pump Timer (7) "G" Control Board
(Do Not Adjust)
Harvest Timer (1 & 2)
b)Harvest Timer (S4 dip switch 1 & 2)
The harvest timer when the thermistor reads 48°F (9°C) at the evaporator outlet and the control board reads the thermistor's 3.9 kΩ signal. The harvest timer is factory set, and generally no adjustment is required. However, a setting longer than the factory setting may be advised in cases where the flush provided at harvest needs to be prolonged for extra cleaning. Before changing this setting, contact Hoshizaki Technical Support at
Note that the
S4 Dip Switch Setting | Time | ||
|
| (seconds) | |
No. 1 | No. 2 | ||
| |||
|
|
| |
OFF | OFF | 60 | |
|
|
| |
ON | OFF | 90 | |
|
|
| |
OFF | ON | 120 | |
ON | ON | 180 | |
|
|
|
32