Problem

Possible Cause

 

Remedy

 

 

 

 

[1] Freeze cycle time is

n) Control Board

1. Float switch

1. Check and reconnect.

long. (continued)

 

connection loose (K5).

 

 

 

 

 

 

 

2. Defective.

2. See "IV.B. Control Board

 

 

 

Check."

[2] Harvest cycle time is

a) Water Supply

1. Water temperature too

1. Increase temperature.

long.

 

cold.

 

 

b) Thermistor

1. Disconnected, loose,

1. Connect, secure, check.

 

 

or defective.

See "V.L. Removal

 

 

 

and Replacement of

 

 

 

Thermistor" and "IV.E.

 

 

 

Thermistor Check."

 

 

 

 

 

c) Control Board

1. Not reading

1. Check and replace. See

 

 

thermistor.

"IV.E. Thermistor Check."

 

 

 

 

 

 

2. Sending voltage to

2. Check and replace. See

 

 

liquid line valve (if

"IV.B. Control Board

 

 

applicable) in harvest.

Check."

 

 

 

 

 

d) Inlet Water Valve

1. Clogged.

1. Clean or replace.

 

e) Evaporator

1. Scaled up.

1. Clean.

 

 

 

 

 

 

2. Damaged.

2. Replace.

 

 

 

 

 

f) Hot Gas Valve

1. Does not open, or

1. Check and replace.

 

 

opens partially.

 

 

 

 

 

 

g) Expansion Valve

1. Wide open in harvest.

1. Check and replace.

 

 

 

 

 

 

2. Bulb loose.

2. Secure bulb.

 

 

 

 

 

h) Water Regulating Valve

1. Open during harvest.

1. Adjust or replace. See

 

(water-cooled model)

 

"V.J. Adjustment of Water

 

 

 

Regulating Valve."

 

 

 

 

 

i) Liquid Line Valve (if

1. Open during harvest

1. Check and replace.

 

applicable)

cycle.

 

 

 

 

 

4. Abnormal Ice

Problem

Possible Cause

 

Remedy

 

 

 

[1] Small cubes.

a) Pump-Out Check Valve

1. Dirty or worn and

1. Clean or replace.

 

 

leaking by.

 

 

 

 

 

 

b) Ice Cube Guide

1. Out of position.

1. Place in position.

 

 

Circulated water falls

 

 

 

into bin.

 

 

 

 

 

 

c) Water System

1. Water supply line too

1. Increase water line size.

 

 

small; requires 3/8"

 

 

 

OD line dedicated per

 

 

 

machine.

 

 

 

2. Water filter clogged or

2. Replace filter or install a

 

 

flow rate too small.

higher flow rate filter.

 

 

 

 

 

d) Inlet Water Valve

1. Dirty mesh filter or

1. Clean.

 

 

orifice.

 

 

 

 

 

 

e) Pump Motor

1. RPM too slow.

1. See chart 1.[5].

 

 

 

 

 

f) Control Board

1. Defective.

1. See "IV.B. Control Board

 

 

 

Check."

66

Page 66
Image 66
Hoshizaki KM-901MWH, KM-901MAH, KM-901MRH/3 service manual Abnormal Ice