f) LED Lights and Audible Alarm Safeties
(1) "E" Control Board: Auxiliary Code T-0, U-0
At startup, a
1 through 4 energize and sequence from initial startup as listed in the table below. Note that the order of the LEDs from the outer edge of the control board is 1, 4, 3, 2.
For details, see "II.B. Sequence of Operation."
Sequence Step | LED | Energized |
| Time LEDs are On | ||
Components | Min. | Max. | Avg. | |||
|
| |||||
4 | WV |
|
| 1 minute | ||
Harvest Cycle | 1, 4, 2 | Comp, FMR, WV, | 2 minutes | 20 minutes | 3 to 5 minutes | |
|
| HGV |
|
|
| |
Freeze Cycle | 1 | Comp, FM/FMR, PM, | 5 minutes | freeze timer 30 to 35 minutes | ||
|
| LLV |
| setting |
| |
1, 4*, 3, 2 | Comp, FMR, WV*, | 10 seconds | 20 seconds | |||
|
| PM, HGV |
|
|
|
The
No. of Beeps | Type of Alarm | Notes | |
(every 3 sec.) | |||
|
| ||
1 | High Evaporator Temp. | Check for harvest problem (stuck HGV or relay), hot | |
| (temperature > 127°F) | water entering unit, stuck HM, or shorted thermistor. | |
| (53°C) |
| |
2 | Harvest Backup Timer | Orange "H TIMER" LED on. | |
| (harvest > 20 min. for two cycles | Check for open thermistor, HGV not opening, TXV or | |
| in a row) | LLV leaking by, low charge, inefficient Comp, or WRV | |
|
| leaking by. | |
3 | Freeze Timer | Yellow "F TIMER" LED on. | |
| (freeze > freeze timer setting for | Check for F/S stuck closed (up), WV leaking by, HGV | |
| two cycles in a row) | leaking by, PM not pumping, TXV not feeding properly, | |
|
| LLV not opening, low charge, HM not bypassing, or | |
|
| inefficient Comp. | |
To reset the above safeties, press the "ALARM RESET" button with the power supply on. | |||
6 | Low Voltage | Red LED turns off if voltage protection operates. | |
| (92Vac±5% or less) | The control voltage safeties automatically reset when | |
7 | High Voltage | voltage is corrected. | |
| (147Vac±5% or more) |
|
Legend: