C. Performance Data

1. KM-901MAH (air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

 

70/21

 

 

90/32

 

 

 

 

70/21

 

874

396

 

832

378

 

785

356

 

 

 

 

80/27

 

842

382

 

778

353

 

736

334

 

 

 

 

90/32

 

832

378

 

732

332

 

687

312

lbs./day

 

kg./day

100/38

 

826

375

 

721

327

 

646

293

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1600

 

 

 

1632

 

 

1658

CONSUMPTION

80/27

 

1625

 

 

 

1675

 

 

1691

 

 

 

 

90/32

 

1632

 

 

 

1710

 

 

1731

watts

 

 

 

100/38

 

1631

 

 

 

1715

 

 

1750

APPROXIMATE WATER

70/21

 

240

0.91

 

212

0.80

 

187

0.71

CONSUMPTION PER 24 HR.

80/27

 

219

0.83

 

175

0.66

 

158

0.60

 

 

m3/day

90/32

 

212

0.80

 

143

0.54

 

123

0.46

gal./day

 

100/38

 

175

0.66

 

139

0.52

 

103

0.39

FREEZING CYCLE TIME

70/21

 

19

 

 

 

20

 

 

22

 

 

 

 

80/27

 

20

 

 

 

22

 

 

24

 

 

 

 

90/32

 

20

 

 

 

24

 

 

26

min.

 

 

 

100/38

 

21

 

 

 

24

 

 

27

HARVEST CYCLE TIME

70/21

 

4.3

 

 

 

3.9

 

 

3.6

 

 

 

 

80/27

 

4.0

 

 

 

3.3

 

 

3.1

 

 

 

 

90/32

 

3.9

 

 

 

2.8

 

 

2.6

min.

 

 

 

100/38

 

3.3

 

 

 

2.7

 

 

2.4

HEAD PRESSURE

70/21

 

219

15.4

 

238

16.7

 

261

18.3

 

 

 

 

80/27

 

234

16.4

 

263

18.5

 

284

20.0

 

 

 

 

90/32

 

238

16.7

 

284

20.0

 

306

21.5

PSIG

kg/cm2G

100/38

 

242

17.0

 

289

20.3

 

327

23.0

SUCTION PRESSURE

70/21

 

35

2.5

 

37

2.6

 

41

2.9

 

 

 

 

80/27

 

36

2.6

 

39

2.7

 

44

3.1

 

 

 

 

90/32

 

37

2.6

 

41

2.9

 

46

3.2

PSIG

kg/cm2G

100/38

 

38

2.7

 

42

3.0

 

50

3.5

TOTAL HEAT OF REJECTION FROM CONDENSER

 

15,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

Note:

1.Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

46

Page 46
Image 46
Hoshizaki KM-901MAH, KM-901MWH, KM-901MRH/3 service manual Performance Data