(6)Shutdown

When MBC is activated (MBC open), the yellow "BC OPEN" LED comes on. The unit then shuts down as outlined in the table below.

Cycle at

Shutdown

Mechanical Bin

 

Control Activation

 

 

 

Fill Cycle

15 seconds after activation.

Harvest Cycle

At the end of the harvest cycle, or up to 15 seconds into the freeze cycle if activated

 

at the end of the harvest cycle.

 

 

Freeze Cycle

15 seconds after activation if activated at least 15 seconds before the 5-minute short

 

cycle protection timer expires. Otherwise, at the end of the next harvest cycle.

 

 

Legend: CB–control board; Comp–compressor; FM–fan motor;

FMR–fan motor-remote; F/S–float switch; HGV–hot gas valve; LLV–liquid line valve; MBC–mechanical bin control; PM–pump motor; WV–inlet water valve