Problem | Possible Cause |
| Remedy |
|
|
|
|
[2] Cloudy or irregular | a) Evaporator | 1. Frozen up. | 1. See chart 2. |
cubes. |
|
|
|
| 2. Scaled up. | 2. Clean | |
|
| ||
|
|
|
|
|
| 3. Damaged. | 3. Replace. |
|
|
|
|
| b) Water System | 1. Water supply line too | 1. Increase water line size. |
|
| small; requires 3/8" |
|
|
| OD line dedicated per |
|
|
| machine. |
|
|
| 2. Water filter clogged or | 2. Replace filter or install a |
|
| flow rate too small. | higher flow rate filter. |
|
|
|
|
|
| 3. High hardness or | 3. Install a water softener or |
|
| contains impurities. | filter. |
|
|
|
|
| c) Spray Guide | 1. Dirty. | 1. Clean. |
|
|
|
|
5. Other
Problem | Possible Cause |
| Remedy | |
|
|
|
| |
[1] Icemaker will not stop | a) Thermostatic Bin | 1. Set too cold. | 1. See "IV.C.1. Thermostatic | |
when bin is filled with | Control |
| Bin Control Check." | |
ice. |
|
|
| |
| 2. Defective. | 2. Replace. | ||
|
| |||
|
|
|
| |
| b) Mechanical Bin Control | 1. Movement restricted. | 1. Check and free. | |
|
| 2. Loose connection. | 2. Check and reconnect. | |
|
|
|
| |
|
| 3. Defective | 3. See "IV.C.2. Mechanical | |
|
|
| Bin Control Check and | |
|
|
| Cleaning." | |
|
|
|
| |
| c) Control Board ("G" | 1. Defective. | 1. See "IV.B. Control Board | |
| control board with |
| Check." | |
| mechanical bin control) |
|
| |
|
|
|
| |
[2] Abnormal noise. | a) Pump Motor | 1. Bearings worn out. | 1. Replace. | |
| b) Fan Motor (except | 1. Bearings worn out. | 1. Replace. | |
|
|
| ||
| 2. Fan blade deformed. | 2. Replace. | ||
|
| |||
|
|
|
| |
|
| 3. Fan blade does not | 3. Replace. | |
|
| move freely. |
| |
|
|
|
| |
| c) Compressor | 1. Bearings worn out or | 1. Replace. | |
|
| cylinder valve broken. |
| |
|
|
|
| |
|
| 2. Mounting pad out of | 2. Reinstall. | |
|
| position. |
| |
| d) Refrigerant Lines | 1. Rub or touch other | 1. Reposition. | |
|
| lines or surfaces. |
| |
|
|
|
| |
[3]Ice in storage bin | a) Drain Line(s) | 1. Plugged. | 1. Clean. | |
often melts. |
|
|
| |
b) Icemaker and Bin | 1. Drains not run | 1. Separate the drain lines. | ||
| ||||
|
| separately. |
| |
|
|
|
| |
| c) Ice Cube Guide | 1. Out of position. | 1. Place in position. | |
|
| Circulated water falls |
| |
|
| into bin. |
| |
|
|
|
|
67