Hoshizaki KM-901MRH/3 VI. Cleaning and Maintenance, Cleaning and Sanitizing Instructions

Models: KM-901MRH/3 KM-901MWH KM-901MAH

1 87
Download 87 pages 28.37 Kb
Page 83
Image 83

VI. Cleaning and Maintenance

WARNING

CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after any cleaning or maintenance is done to the unit. Make sure that none have fallen into the storage bin.

A. Cleaning and Sanitizing Instructions

Hoshizaki recommends cleaning and sanitizing this unit at least once a year. More frequent cleaning and sanitizing, however, may be required in some existing water conditions.

WARNING

1.To prevent injury to individuals and damage to the icemaker, do not use ammonia type cleaners.

2.Carefully follow any instructions provided with the bottles of cleaning and sanitizing solution.

3.Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing solutions from coming into contact with skin or eyes.

4.To prevent damage to the water pump seal, do not operate the icemaker with the control switch in the "WASH" position when the water tank is empty.

IMPORTANT

1.The cleaning valve is opened during cleaning and sanitizing to allow solution flow to the inside of the evaporator. It should be closed for all icemaking operation. The compressor will not operate unless this valve is completely closed.

2.To close the cleaning valve, the valve handle should be at a right angle to the valve body. To open the cleaning valve, the valve handle should be

parallel to the valve body.

CLOSED

OPEN

Normal Icemaking Operation

Cleaning and Sanitizing Operation

 

(allows solution flow to the inside

 

of the evaporator)

83

Page 83
Image 83
Hoshizaki KM-901MRH/3, KM-901MWH, KM-901MAH service manual VI. Cleaning and Maintenance, Cleaning and Sanitizing Instructions