4. KM-901MRH3 (remote air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

899

408

 

874

397

 

817

371

 

 

 

 

80/27

880

399

 

842

382

 

772

350

 

 

 

 

90/32

874

397

 

815

370

 

749

340

lbs./day

 

kg./day

100/38

855

388

 

800

363

 

689

313

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1670

 

 

1717

 

 

1755

CONSUMPTION

80/27

 

1706

 

 

1779

 

 

1803

 

 

 

 

90/32

 

1717

 

 

1830

 

 

1861

watts

 

 

 

100/38

 

1716

 

 

1837

 

 

1890

APPROXIMATE WATER

70/21

254

0.96

 

222

0.84

 

203

0.77

CONSUMPTION PER 24 HR.

80/27

230

0.87

 

181

0.69

 

174

0.66

 

 

 

 

90/32

222

0.84

 

147

0.56

 

134

0.51

gal./day

 

m3/day

100/38

185

0.70

 

144

0.54

 

123

0.46

FREEZING CYCLE TIME

70/21

 

19

 

 

20

 

 

21

 

 

 

 

80/27

 

20

 

 

21

 

 

23

 

 

 

 

90/32

 

20

 

 

22

 

 

24

min.

 

 

 

100/38

 

20

 

 

23

 

 

26

HARVEST CYCLE TIME

70/21

 

4.4

 

 

3.9

 

 

3.6

 

 

 

 

80/27

 

4.0

 

 

3.3

 

 

3.2

 

 

 

 

90/32

 

3.9

 

 

2.8

 

 

2.6

min.

 

 

 

100/38

 

3.4

 

 

2.7

 

 

2.4

HEAD PRESSURE

70/21

206

14.5

 

225

15.8

 

248

17.5

 

 

 

 

80/27

220

15.5

 

249

17.5

 

272

19.1

 

 

 

 

90/32

225

15.8

 

270

19.0

 

293

20.6

PSIG

kg/cm2G

100/38

229

16.1

 

275

19.4

 

315

22.1

SUCTION PRESSURE

70/21

36

2.5

 

38

2.7

 

41

2.9

 

 

 

 

80/27

37

2.6

 

40

2.8

 

44

3.1

 

 

 

 

90/32

38

2.7

 

42

3.0

 

46

3.2

PSIG

kg/cm2G

100/38

39

2.7

 

43

3.0

 

49

3.4

TOTAL HEAT OF REJECTION FROM CONDENSER

14,100

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,200

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

121

CU. IN (URC-9F)

Note:

1.Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

49

Page 49
Image 49
Hoshizaki KM-901MAH, KM-901MWH, KM-901MRH/3 service manual KM-901MRH3 remote air-cooled