Problem | Possible Cause |
| Remedy | |
|
|
|
| |
[1] The icemaker will not | h) Transformer | 1. Coil winding open or | 1. Replace. | |
start. (continued) |
|
| shorted. |
|
| i) | Wiring to Control Board | 1. Loose connections or | 1. Check for continuity and |
|
|
| open. | replace. |
|
|
|
|
|
| j) | Interlock Switch | 1. Open position. | 1. Move to closed position. |
|
| (Cleaning Valve) |
|
|
|
| 2. Bad contacts. | 2. Check for continuity and | |
|
|
| ||
|
|
|
| replace. |
|
|
|
| |
| k) Mechanical Bin Control | 1. Movement restricted. | 1. Check and free. | |
|
|
| 2. Defective | 2. See "IV.C.2. Mechanical |
|
|
|
| Bin Control Check and |
|
|
|
| Cleaning." |
| l) | Thermistor | 1. Leads shorted or open | 1. See "IV.E. Thermistor |
|
|
| and high temperature | Check." |
|
|
| or harvest backup |
|
|
|
| timer safety operates |
|
|
|
| (1 beep or 2 beep |
|
|
|
| alarm). |
|
|
|
|
| |
| m)Hot Gas Valve | 1. Continues to open | 1. Check for hot gas valve | |
|
|
| in freeze cycle and | stuck open and replace. |
|
|
| freeze timer safety |
|
|
|
| operates (3 beep |
|
|
|
| alarm). |
|
|
|
|
| |
| n) Inlet Water Valve | 1. Mesh filter or orifice | 1. Clean. | |
|
|
| gets clogged and |
|
|
|
| water supply cycle |
|
|
|
| does not finish. |
|
|
|
|
|
|
|
|
| 2. Coil winding open. | 2. Replace. |
|
|
| 3. Wiring to inlet water | 3. Check for loose connection |
|
|
| valve. | or open, and replace. |
|
|
|
| |
| o) Float Switch | 1. Bad contacts. | 1. Check for continuity and | |
|
|
|
| replace. |
|
|
|
|
|
|
|
| 2. Defective switch. | 2. Clean or replace. See "IV. |
|
|
|
| D. Float Switch Check and |
|
|
|
| Cleaning." |
|
|
|
| |
| p) Control Board | 1. Defective or in alarm. | 1. See "IV.B. Control Board | |
|
|
|
| Check." |
[2] Fill cycle will not | a) Water Supply | 1. Water supply off or | 1. Check and get | |
terminate. |
|
| pressure too low. | recommended pressure. |
|
|
|
| |
| b) Float Switch | 1. Connector | 1. Reconnect. | |
|
|
| disconnected. |
|
|
|
|
|
|
|
|
| 2. Float does not move | 2. Clean or replace. See "IV. |
|
|
| freely or switch | D. Float Switch Check and |
|
|
| defective switch. | Cleaning." |
|
|
|
| |
| c) Control Board | 1. Defective. | 1. See "IV.B. Control Board | |
|
|
|
| Check." |
61