Hoshizaki KM-901MAH, KM-901MWH, KM-901MRH/3 Bin Control Selector/Harvest Pump Timer S4 dip switch

Models: KM-901MRH/3 KM-901MWH KM-901MAH

1 87
Download 87 pages 28.37 Kb
Page 34
Image 34

e)Bin Control Selector/Harvest Pump Timer (S4 dip switch 7)

Depending on the control board, S4 dip switch 7 is either a bin control selector or harvest pump timer.

CAUTION

Do not adjust. This dip switch must be left in the factory default position or this unit will not operate correctly.

(1) Bin Control Selector, "E" Control Board: Auxiliary Code T-0, U-0

Factory set for proper operation. Do not adjust. When set to the on position on a unit with a thermostatic bin control, a 5-beep alarm sounds (open circuit) and the unit does not operate.

"E" Control Board

S4 Dip Switch Setting

Bin Control

 

No. 7

 

 

 

ON

Mechanical

 

 

OFF

Thermostatic

 

 

(2) Harvest Pump Timer, "G" Control Board: Auxiliary Code U-1 and Later

Factory set for proper operation. Do not adjust. Depending on the harvest pump timer setting, the pump motor energizes and runs the last 0 or 50 seconds of harvest. The water valve is energized during harvest for a maximum of 6 minutes or the length

of harvest minus 0 or 50 seconds (determined by the harvest pump timer setting), whichever is shorter. CAUTION! Do not adjust S4 dip switch 7 out of the factory default position on this model. This dip switch must be left in the factory default position or this unit will not operate correctly.

"G" Control Board

S4 Dip Switch Setting

Pump Motor

No. 7

Time (seconds)

 

 

ON

50

 

 

OFF

0

f) Factory Use (S4 dip switch 8)

Factory set for proper operation. Do not adjust. This must be left in the factory default position.