3. KM-901MRH (remote air-cooled)

APPROXIMATE ICE

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

 

70/21

 

 

90/32

 

 

 

 

70/21

889

403

 

859

389

 

803

364

 

 

 

 

80/27

866

393

 

818

371

 

755

343

 

 

 

 

90/32

859

389

 

785

356

 

724

328

lbs./day

 

kg./day

100/38

843

382

 

771

350

 

668

303

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

1590

 

 

1643

 

 

1664

CONSUMPTION

80/27

 

1630

 

 

1712

 

 

1705

 

 

 

 

90/32

 

1643

 

 

1770

 

 

1775

watts

 

 

 

100/38

 

1630

 

 

1771

 

 

1780

APPROXIMATE WATER

70/21

246

0.93

 

219

0.83

 

194

0.74

CONSUMPTION PER 24 HR.

80/27

225

0.85

 

182

0.69

 

165

0.63

 

 

 

 

90/32

219

0.83

 

152

0.57

 

131

0.50

gal./day

 

m3/day

100/38

182

0.69

 

147

0.56

 

112

0.42

FREEZING CYCLE TIME

70/21

 

18

 

 

20

 

 

21

 

 

 

 

80/27

 

19

 

 

21

 

 

23

 

 

 

 

90/32

 

20

 

 

22

 

 

24

min.

 

 

 

100/38

 

20

 

 

23

 

 

26

HARVEST CYCLE TIME

70/21

 

4.3

 

 

3.9

 

 

3.6

 

 

 

 

80/27

 

4.0

 

 

3.4

 

 

3.2

 

 

 

 

90/32

 

3.9

 

 

2.9

 

 

2.7

min.

 

 

 

100/38

 

3.4

 

 

2.8

 

 

2.4

HEAD PRESSURE

70/21

208

14.6

 

229

16.1

 

252

17.7

 

 

 

 

80/27

224

15.7

 

256

18.0

 

277

19.5

 

 

 

 

90/32

229

16.1

 

279

19.6

 

301

21.2

PSIG

kg/cm2G

100/38

232

16.3

 

284

20.0

 

322

22.6

SUCTION PRESSURE

70/21

35

2.5

 

37

2.6

 

41

2.9

 

 

 

 

80/27

37

2.6

 

40

2.8

 

45

3.1

 

 

 

 

90/32

37

2.6

 

43

3.0

 

47

3.3

PSIG

kg/cm2G

100/38

38

2.7

 

44

3.1

 

51

3.6

TOTAL HEAT OF REJECTION FROM CONDENSER

14,000

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,200

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

121

CU. IN (URC-9F)

Note:

1.Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

48

Page 48
Image 48
Hoshizaki KM-901MWH, KM-901MAH, KM-901MRH/3 service manual KM-901MRH remote air-cooled