g) Freeze Timer (S4 dip switch 9 & 10)

CAUTION

Adjust to proper specification, or the unit may not operate correctly.

The freeze timer setting determines the maximum allowed freeze time to prevent possible freeze-up issues. Upon termination of the freeze timer, the control board initiates the harvest cycle. After 2 consecutive freeze timer terminations, the control board shuts down the icemaker. In this case, see "IV.F.3. Low Ice Production" for possible solutions. The freeze timer is factory set, and generally no adjustment

is required. Before changing this setting, contact Hoshizaki Technical Support at 1800233-1940 for recommendations.

S4 Dip Switch Setting

Time

 

 

(minutes)

No. 9

No. 10

 

 

 

 

OFF

OFF

60

 

 

 

OFF

ON

50

 

 

 

ON

OFF

70

 

 

 

ON

ON

60

 

 

 

h) Float Switch Control (S5 dip switch 1): "G" Control Board

CAUTION

Do not adjust. This must be left in the factory default position or the unit will not operate correctly.

Factory set. S5 dip switch 1 allows for single or double float switch applications. The KM901MAH, KM-901MWH, and KM-901MRH/3 use a single float switch.

i) Refill Counter (S5 dip switch 2 through 5): "G" Control Board

CAUTION

Do not adjust. These must be left in the factory default position or the unit will not operate correctly.

Factory set. S5 dip switch 2 through 5 allows for refills during the freeze cycle. The KM901MAH, KM901MWH, and KM-901MRH/3 do not refill.