g) Freeze Timer (S4 dip switch 9 & 10)
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent possible
is required. Before changing this setting, contact Hoshizaki Technical Support at
S4 Dip Switch Setting | Time | ||
|
| (minutes) | |
No. 9 | No. 10 | ||
| |||
|
|
| |
OFF | OFF | 60 | |
|
|
| |
OFF | ON | 50 | |
|
|
| |
ON | OFF | 70 | |
|
|
| |
ON | ON | 60 | |
|
|
|
h) Float Switch Control (S5 dip switch 1): "G" Control Board
CAUTION
Do not adjust. This must be left in the factory default position or the unit will not operate correctly.
Factory set. S5 dip switch 1 allows for single or double float switch applications. The KM‑901MAH,
i) Refill Counter (S5 dip switch 2 through 5): "G" Control Board
CAUTION
Do not adjust. These must be left in the factory default position or the unit will not operate correctly.
Factory set. S5 dip switch 2 through 5 allows for refills during the freeze cycle. The KM‑901MAH, KM901MWH, and