Hoshizaki KM-901MAH, KM-901MWH, KM-901MRH/3 service manual Float Switch Cleaning

Models: KM-901MRH/3 KM-901MWH KM-901MAH

1 87
Download 87 pages 28.37 Kb
Page 58
Image 58

2. Float Switch Cleaning

Depending on local water conditions, scale may build up on the float switch. Scale on the switch can cause the float to stick. In this case, the float switch should be cleaned.

1)Turn off the power supply.

2)Remove the front panel, then move the control switch to the "OFF" position.

3)Remove the base cover, then disconnect one end of the pump tubing to drain the water tank. See Fig. 2. After the water tank has drained, reconnect the pump tubing.

4)Disconnect the vent tube and the flush tube from the top of the float switch, then remove the float switch assembly and remove the float switch assembly and remove the rubber boot from the bottom of the float switch assembly. See Fig. 3.

5)Remove the retainer rod from the bottom of the float switch housing, then remove the float. Be careful not to bend the retainer rod excessively when removing it.

6)Wipe down the float switch housing, shaft, float, and retainer rod with a mixture of

1 part of recommended cleaner Hoshizaki "Scale Away" or "LIMEAWAY" (Economics Laboratory, Inc.) and 25 parts of warm water. Clean the inside of the rubber boot and hose with cleaning solution. Rinse the parts thoroughly with clean water.

7)Reassemble the float switch assembly and replace it and the rubber boot in their correct positions. Reconnect the vent tube and the flush tube.

8)Move the control switch to the "ICE" position.

9)Replace the front panel in its correct position.

 

Vent

 

Flush

 

Shaft

 

Float Switch

 

Housing

 

Float

 

Retainer Rod

 

Rubber Boot

Fig. 3

and Hose

 

58

Page 58
Image 58
Hoshizaki KM-901MAH, KM-901MWH, KM-901MRH/3 service manual Float Switch Cleaning