Command | ASCII Command | Response | Additional Description | |
(Host to Unit) | (Unit to Host) | |||
|
|
Relay Functions (RS models only)
Pulse relay | X@*3*X# O | Rly X@*X2# ] |
Example: | 2*3*1O | Rly2*1 ] |
Toggle relay | X@*2 O | Rly X@*X2# ] |
Force relay on | X@*1 O | Rly X@*1 ] |
Force relay off | X@*0 O | Rly X@*0 ] |
View relay state | X@ O | X2# ] |
Set the length X# of the pulse specified for relay port X@. Values for X# represent increments of 0.5 seconds and can range from 1 (0.5 seconds) to 255 (approximately
130 seconds). The MLC response includes status X2# for the specified relay port.
For X@: 1 = Relay 1; 2 = Relay 2.
For X2#: 0 = open (disengaged; 1 = closed (engaged).
Relay port 2 will remain closed for pulse intervals of 0.5 seconds.
Close and open relay port X@. Each time the command is issued, the MLC toggles between the On and Off states.
The MLC response includes status X2# for the specified relay port.
Set relay port X@ to remain closed (on).
Set relay port X@ to remain open (off).
Show state X2# of relay port X@. For X2#: 0 = open; 1 = closed.
Digital Input Data Port (RS models only)
View digital input state | ] | X^ ] | View status X^ of the Digital |
|
|
| Input port. For X^: |
|
|
| 0 = low; 1 = high. |
Front Panel Lockout (Executive Mode) |
|
| |
Off | 0X | Exe0 ] | Unlock front panel buttons. |
On | 1X | Exe1 ] | Lock all front panel buttons. |
View | X | X1! ] | View front panel lockout status. |
|
|
| X1!. For X1!, 0 = off; 1 = on. |
Device Naming |
|
|
|
Set unit name | E X1@ CN } | Ipn•X1@ ] | Set name X1@ for the MLC. X1@ |
|
|
| can be up to 24 alphanumeric |
|
|
| characters. The first character |
|
|
| must be alphabetic; the last |
|
|
| character cannot be a hyphen or |
|
|
| minus sign. No blank or space |
|
|
| characters are permitted. |
Set unit name to factory | E•CN } | Ipn•X4( ] | Set the name of the MLC to its |
default |
|
| factory default name X4(. |
|
|
| X4( is: |
|
|
| • |
|
|
| • |
|
|
| • |
View unit name | E CN } | X1@ ] | Show the name of the MLC. |
MLC 60 Series MediaLink Controllers • SIS Control | 59 |