DCN Wireless Installation and User Instructions System Design and Planning
en 18
2.7.5.3Total power consumption
Do as follows:
1 Find the power consumption of each device from the consumption table (refer to table 2.2).
2 Add together the power used by all the devices. The result is the total power consumption of the devices that are connected to the socket.
2.7.5.4Length of the longest extension cable
sequence
Do as follows:
1Add together the lengths of all extension cables in the longest sequence.
For example, an extension cable of 20 m is connected directly to a DCN socket of the central control unit. To the extension cable, a trunk splitter is connected. To each
2.7.5.5Graph
The power correction graph (refer to figure 2.3) corrects the power level to compensate for the extension cables. Do as follows:
1Find the total power consumption (refer to section 2.7.5.3) on the vertical axis (Y) of the power
correction graph. For example, 40 W.
2Find the length of the longest extension cable sequence (refer to section 2.7.5.4) on the horizontal axis (X) of the power correction graph. For example,
60 m.
3The intersection of both values gives the necessary power from the socket. For example, 53 W.
Y: Power (Watt)
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
81 |
|
|
|
|
|
|
|
|
|
|
|
76 | 84 |
|
|
|
|
|
|
|
|
|
|
70 | 78 |
|
|
|
|
|
|
|
|
|
|
65 | 72 | 80 |
|
|
|
|
|
|
|
|
|
60 | 66 | 73 | 82 |
|
|
|
|
|
|
|
|
54 | 60 | 66 | 75 | 85 |
|
|
|
|
|
|
|
49 | 54 | 60 | 67 | 77 | 83 |
|
|
|
|
|
|
43 | 48 | 53 | 60 | 68 | 73 | 80 |
|
|
|
|
|
38 | 42 | 46 | 52 | 60 | 64 | 70 | 76 | 84 |
|
|
|
32 | 36 | 40 | 45 | 51 | 55 | 60 | 65 | 72 | 80 |
|
|
27 | 30 | 33 | 37 | 42 | 46 | 50 | 54 | 60 | 66 | 75 | 85 |
21 | 24 | 26 | 30 | 34 | 36 | 40 | 43 | 48 | 53 | 60 | 68 73 |
16 | 18 | 20 | 22 | 25 | 27 | 30 | 32 | 36 | 40 | 45 | 51 55 |
11 | 12 | 13 | 15 | 17 | 18 | 20 | 21 | 24 | 26 | 30 | 34 36 |
6 | 6 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 15 | 17 18 |
20 | 40 | 60 | 80 | 100 | 120 | 140 | 160 | 180 | 200 | 220 | 240 250 |
| X: Extension cable (m) | ||
| |||
+ |
|
|
|
|
|
figure 2.3: Power correction graph
Bosch Security Systems