DCN Wireless Installation and User Instructions Central Devices
en 41
10.3.2 | S600 switches |
|
table 10.1: S600 switches (* = default) | ||
Switch | Position | Description |
ON* | Reserved. Do not change the position of this switch. | |
| OFF |
|
ON | Reserved. Do not change the position of this switch. | |
| OFF* |
|
ON | Reserved. Do not change the position of this switch. | |
| OFF* |
|
ON | Reserved. Do not change the position of this switch. | |
| OFF* |
|
ON | Reserved. Do not change the position of this switch. | |
| OFF* |
|
|
|
|
ON | Reserved. Do not change the position of this switch. | |
| OFF* |
|
ON | Reserved. Do not change the position of this switch. | |
| OFF* |
|
ON | Enables the download of new firmware. | |
| OFF* | Normal operation. |
10.3.3 RS232 configuration
Use the S500 switches to configure the RS232 ports of the central control unit (refer to table 10.2 and table 10.3).
table 10.2: RS232 protocol (* = default)
Protocol | Port 1 |
| Port 2 |
|
| ||||
Open interface | Off | Off | Off | Off |
Terminal | Off | On | Off | On |
|
|
|
|
|
Full | On* | Off* | On | Off |
Camera control | On | On | On* | On* |
table 10.3: RS232 baudrate (* = default) |
|
|
| |
Baudrate | Port 1 |
| Port 2 |
|
| ||||
9.6k | Off | Off | Off | Off |
19.2k | Off | On | Off* | On* |
57.6k | On | Off | On | Off |
115.2k | On* | On* | On | On |
Bosch Security Systems