Bosch Appliances 9922 141 70691 en manual Repetition rate, Audio routing modes, Recorder

Page 70

DCN Wireless Installation and User Instructions Central Devices

en 70

12.5Repetition rate

When other wireless networks cause interference, the audio quality can decrease. In some cases, you can increase the repetition rate of the audio packets to improve the audio quality. You can change the repetition rate of the audio packets with the

4Jc Repetition menu item.

Note

When you increase the repetition rate, the audio delay is increased.

12.6Audio routing modes

12.6.1 Introduction

You can set the audio routing mode of the system with the 4E Routing I/O 2 menu item. The functions of audio input 1 and audio output 1 of the central control unit are the same in each audio routing mode. The signal on audio input 1 is always added to the floor signal. The signal on audio output 1 is always suitable to connect the system to an external public address system (for example, Praesideo).

12.6.2 Recorder

In the Recorder mode, audio output 2 of the central control unit transmits a signal that you can connect to an external audio recorder (refer to figure 12.1). The central control unit has no effect on the volume level of the signal.

In the Recorder mode, the signal on audio input 2 of the central control unit is added to the floor signal.

 

C

 

1

 

 

 

 

3<

 

 

 

C

 

 

 

O

 

 

 

 

 

2

C

I

 

 

 

I

 

2

 

DCN-SW

+

1

 

 

 

 

 

Legend

 

 

C

Contribution devices

 

DCN-WCCU

I

Interpretation devices

 

C

+

Optical network

 

 

+

Chime

figure 12.1: Recorder

Bosch Security Systems 2007-02 9922 141 70691 en

Image 70
Contents DCN Wireless Page Important Safeguards Disclaimers Digital version Admonitions and notes About this manualFunction SignsElectro-static discharges Conversion tablesTable of Contents 10.1 105 Intentionally left blank System Design and Planning Introduction Wireless network designFrequency band LimitsGHz 400 412 417 422 427 432 437 442 447 452 484 GHz Calculation tool DCN designConcepts Power capacity Control capacityPower supplies DCN power supply DCN-WCCUCable lengths DCN-WCCU DCN-EPSExamples Cable lengthsExample with interpreter desks DCN-IDESK Interpreter booths with LBB4114/00 Interpretation devicesDCN-CCU2 DCN-WAP1 Optical network designNodes INT-TX041 INT-TX082 INT-TX164 INT-TX328 PRS-4DEX41Cabling Power supplyDefinitions Cable couplers Optical fiber lengthMaximum cable length Bending Example layoutsCoiling Extended optical network Basic optical networkRedundant cables Tap-offs Redundant optical network with tap-offCamera control Infra-red wireless language distributionScenarios CobraNet User set-up Headphones/headsetsInterpreter booths Public areas and walkwaysDevice set-up Acoustic feedback Acoustic feedbackGeneral Technical dataSystem electrical and electro-acoustic characteristics Transmission linksCombined devices from input to output SafetyEnvironmental conditions Combined devices from input to outputElectro-magnetic compatibility Wireless devicesWireless devices Electromagnetic compatibilityMiscellaneous MiscellaneousIntentionally left blank Central Devices Controls, connectors and indicators DCN-WCCU Wireless Central Control UnitFront view Internal settings Rear viewInternal settings 10.3.3 RS232 configuration Watchdog Internal back-up batteryGround Voltage selector InstallationExternal connections Fuses10 DCN connection 10.5.2 DCNOptical network LEDAudio inputs HeadphonesXLR 14 Audio input details, line level signals Audio outputsFault contact 16 Audio output details10.5.8 RS232 ports 19 RS232 portsWAP Configuration menuCCU Navigation and operation 20 VU meterTo select a parameter Bosch Security Systems 2007-02 9922 141 70691 en Main Fault status21 Messages low to high importance Monitoring 22 Monitoring sub-menu * = default23 DCN-WCCU Enquiry sub-menu * = default DCN-WCCU Enquiry24 DCN-WAP Enquiry sub-menu * = default DCN-WAP EnquiryNOM Setup25 Setup sub-menu * = default PTT27 Loudspkr sub-menu * = default 26 Setup sub-menu * = defaultLoudspkr 29 Wireless sub-menu * = default Wireless28 Intercom sub-menu * = default Intercom31 Defaults sub-menu * = default Defaults30 De-init sub-menu * = default De-initDCN-WAP Wireless Access Point FirmwareWall or ceiling 11.4 Installation11.4.1 General Tripod LogoConfiguration System IDPower values Power valueCarrier Operation CC B aMenu of the central control unit is open. Use these menu Initialization System configuration System Wireless modes Override Microphone modesOpen 12.4.4 PTTAudio routing modes Repetition rateRecorder Equalized PA InsertionFloor distribution Erase requests-to-speak and speakersMix-minus Location of the chairman IntercomLocation of the operator Start the system System operationStop the system Contribution Devices Left and right sides DCN-WDU Wireless Discussion Units14.2.1 Top Bottom sideDCN-WD DCN-WDD DCN-WDV Side views Microphone sensitivity Microphone sensitivityVolume restore function Headphones level reductionSingle delegate ProcedureModes ChairmanDual delegate Single delegate with auxiliary controlMicrophone buttons Remove microphone buttonsBattery 10 Install microphone buttonsSubscription RimsHeadphones sockets, details Erase the subscriptionDeactivation External power supplyActivation Quick reference cardStatus LEDs Attendance LEDAttendance LED Electrical and acoustic properties DCN-MICL, DCN-MICS Pluggable MicrophonesTypes and lengths Compatible devicesMicrophone plug, connection DCN-WLIION Battery Pack Battery capacityCapacity LEDs DCN-WCH05 Battery Charger Battery pack containers HoldInstallation, wall WallPower inlet Installation, multiple battery chargersLoop-through socket Charge level LEDsDCN-WPS Power Supply Adapter Electrical propertiesDCN-DDI Dual Delegate Interface Dual delegate interfaceInput adjustment switch * = default Input type switch * = defaultSignal level switch * = default Ambient microphone DCN-FHHIntercom handset 19.6.1 DCNDCN connections Connections Audio inputsCmrr DCN-WFCD10 Flight Case for Wireless Discussion Units DCN-WFCCU Flight Case for DCN-WCCUIntentionally left blank Appendices Table A.2 Analog outputs Audio levelsTable A.3 Monitor DCN-DDI Table A.6 Dual delegate interfaceExtension power supply DCN Next Gen Central control unit wirelessCentral control unit wireless UL Product indexWireless discussion unit with voting Wireless discussion unitWireless dual discussion unit Power Supply AdapterStatements for FCC & Industry Canada Declarations DCN Wireless Installation and User Instructions Appendices Page Page Page Page Page Page Page For more information visit