Basic standard ESD:
According EN
Contact discharge: 4 kV and air discharge: 8 kV
Basic standard mains harmonics and voltage fluctuations, flicker: According EN
Basic standard RF electromagnetic fields:
According EN
RF conducted: 150 kHz - 80 MHz: 3 Vrms
RF radiated 80 - 1000 MHz: 3 V/m
Cellular telephone (GSM) dummy test: at 20 cm speech distance
Criteria: not effecting normal operation. Magnetic immunity:
Rack mounting: 50 Hz - 10 kHz: 4 - 0.4 A/m
No rack mounting: 50 Hz - 10 kHz: 3 - 0.03 A/m
Basic standard low energy electrical fast transients, bursts: According EN
Mains: fast transients: 1 kV; signal and control data lines: 0.5 kV Basic standard high energy surges:
According EN
Mains: surges: 1 kV CM and 0.5 kV DM.
Basic standard voltage dips, short interruptions, variations: According EN
Mains: voltage dips 100% for 1 period, 60% for 5 periods, > 95% for 5 seconds.