DCN Wireless Installation and User Instructions Central Devices
en 47
You can select the procedure that is used to send audio signals through the central control unit with the available audio routing modes (refer to 10.6.8).
table 10.16: Audio output details
Number of connections:
•1x XLR plug for each audio output
•1x double cinch socket for each audio output Location:
Rear side Cable: Shielded cable Maximum level: Refer to appendix A
Nominal level (audio output 1): Refer to appendix A
Nominal level (audio output 2): Refer to appendix A Frequency response:
Impedance: < 100 Ω
< 0.1% @ 100 Hz @ - 3 dB of the max. input
10.5.7 Fault contact
Use the fault contact to send the condition of the central control unit to external devices. If the central control unit operates correctly, the OK pins are internally connected. The central control unit internally connects the Fail pins when:
•The central control unit is stopped.
•The internal power supply unit operates incorrectly.
•The central control unit does a reset.
OK Fail
figure 10.10: Fault contact
table 10.17: Fault contact
Number of connections:
Location:
Rear side
Signal:
Voltage:
Max. 24 V(DC), 15 V(AC)
Current:
Max. 500 mA
Bosch Security Systems