DCN Wireless Installation and User Instructions Central Devices
en 43
10.4Installation
Install the central control unit in a
10.5External connections
10.5.1 Power supply
To connect the central control unit to a mains power supply do as follows:
Note
The
1Set the voltage selector on the rear of the central control unit to the correct position (refer to table 10.8).
figure 10.3: Installation
table 10.7: Physical characteristics
Dimensions (h x w x d), flat surface:
92 x 440 x 400 mm (without brackets, with feet)
Dimensions (h x w x d),
88 x 483 x 400 mm (with brackets, without feet)
Weight:
6.7 kg (without brackets, without feet)
Note
When you install the central control unit in a
table 10.8: Voltage selector
Power supply voltage | Voltage selector |
90 to 132 V(AC) | 115 |
198 to 264 V(AC) | 230 |
2Make sure that the fuse holder in the rear of the central control unit contains the correct fuse (refer to table 10.9).
table 10.9: Fuses
Voltage selector | Fuse |
115 | T2.5A 250 V (UL 248) |
230 | T2AH 250 V (IEC 60127) |
3Connect a locally approved power cable to the central control unit (refer to figure 10.4).
figure 10.4: Power supply
Bosch Security Systems