Thermo Products CMA2-75N, CMA1-50N service manual Table Of Contents, Section

Page 2

 

 

 

TABLE OF CONTENTS

 

SECTION

 

BEGINNING PAGE

I.

SAFETY INFORMATION

 

1

II.

FURNACE SPECIFICATIONS

 

6

III. GENERAL INSTRUCTIONS AND CLEARANCES

7

IV. GENERAL INSTALLATION

 

9

 

A. FURNACE LOCATION

 

9

 

B. BASE INSTALLATION

 

12

 

C. ALCOVE INSTALLATION

 

13

 

D. CLOSET INSTALLATION

 

14

 

E. FUEL PIPING

 

15

 

F. GENERAL VENTING REQUIREMENTS

16

 

G. CONNECTING THE EXHAUST VENT, AND COMBUSTION

18

 

AIR INTAKE

 

 

 

H. DIRECT VENTING THROUGH A SIDEWALL

19

 

I. INSTALLATION OF OUTSIDE EXHAUST/INTAKE TERMINATIONS

23

 

J. CONNECTING THE FURNACE TO ROOF VENT/ INTAKE TERMINATIONS

24

 

K. CONDENSATE DRAIN LINE AND TRAP ASSEMBLY

26

 

L. ELECTRICAL WIRING

 

27

V.

STARTING THE UNIT

 

32

 

A. SEQUENCE OF OPERATION

32

 

B. INITIAL START-UP

 

34

 

C. ADJUSTMENT OF BTU INPUT RATE

35

 

D. BURNER ADJUSTMENT

 

36

 

E. SETTING TEMPERATURE RISE

37

 

F. FURNACE CHECK-OUT PROCEDURE

38

VI. INSTALLER'S INSTRUCTIONS TO USER

39

VII. DEALER MAINTENANCE

 

39

 

A. ELECTRICAL

 

40

 

B. GENERAL INSPECTION

 

40

 

C. HEAT EXCHANGER

 

41

 

D. HOUSE AIR BLOWER

 

41

 

E. RETURN AIR FILTER

 

41

VIII. TROUBLE SHOOTING

 

42

APPENDIX-A

REPLACEMENT PARTS

49

APPENDIX-B

WIRING DIAGRAM

51

WARRANTY

 

 

52

REFERENCED PUBLICATIONS:

FOR COPIES CONTACT:

 

NATIONAL FUEL GAS CODE

NATIONAL FIRE PROTECTION ASSOCIATION

 

NFPA 54/ANSI-Z233.1

 

1 BATTERYMARCH PARK

 

(LATEST EDITION)

 

P.O. BOX 9101

 

 

 

 

QUINCY, MA 02269-9101

 

Image 2
Contents GAS FIRED HIGH EFFICIENCY FURNACE INSTALLATION AND SERVICE MANUALFOR YOUR SAFETY DOWN FLOW & DIRECT VENT SEALED COMBUSTIONTABLE OF CONTENTS SECTIONI. SAFETY INFORMATION Page Page The vent and air intake elbows must be kept away from bushes, shrubs or any vegetation that may restrict the flow of flue products. It must also be kept clear of any leaves, weeds or other combustible materials. Keep the vent hood clear of snow. Avoid locating the terminals in areas where standing water or condensate drippage may be a problem 1.A windows be opened MODEL II. FURNACE SPECIFICATIONS - CMA SERIESDIMENSIONS GAS SUPPLY PRESSUREINSTALLATION PARTS PACKAGE COMBUSTIBLE MATERIAL.” COMBUSTIBLE MATERIAL NON-COMBUSTIBLEMATERIALTable IV. GENERAL INSTALLATION A.FURNACE LOCATIONMODELS CMA Figure 1B Combustible Floor Base Model: 70-BASE Figure 1ACoil Cabinet Cottage Base Model: 01COT-BASE Figure 1C Figure Figure B. BASE INSTALLATION1. Combustible Floor Base Model: 70 BASE Figure C. ALCOVE INSTALLATION2. Cottage Base Model: 01COT BASE D. CLOSET INSTALLATION FigureE. FUEL PIPING F.GENERAL VENTING REQUIREMENTS MAXIMUM VENT LENGTH TableFigure 6. CMA*-75SHOWN H. Direct Venting Through a Sidewall 1. Vent And Combustion Air Pipes2. Exhaust Vent Termination Elbow Sidewall Venting Page 4. Vent Terminal Location Guidelines Terminations 5.Secure plate to roof Figure FigureFigure K.CONDENSATE DRAIN LINE AND TRAP ASSEMBLY 3.Connection Of Room Thermostat Wires Figure L.ELECTRICAL WIRING2.Connection Of Power Supply Wires 1. Electrical Branch Supply CircuitElectrical Wire Diameter AWG 24 22 20 18 4. BLOWER MOTOR SPEED WIRING Figure Static CMA1-50Speed Tap \ PressureStatic CMA2-75Speed Tap \ Pressure5. FIELD WIRING AND REPLACING WIRING V.STARTING THE UNIT A. SEQUENCE OF OPERATIONS MAIN BURNER OPERATION CALL FOR HEAT SATISFIED B.INITIAL START UP OPERATING INSTRUCTIONSC.ADJUSTMENT OF BTU INPUT RATE GAS PRESSURE CHART FOR CMA* MODEL FURNACES D.BURNER ADJUSTMENTE.SETTING TEMPERATURE RISE FigureF.FURNACE CHECKOUT PROCEDURE VI. INSTALLERS INSTRUCTIONS TO USER VII. DEALER MAINTENANCEA.ELECTRICAL 2.CONDENSATE LINE/TRAP ASSEMBLY4. INDUCER BLOWER ASSEMBLY B.GENERAL INSPECTIONC.HEAT EXCHANGER 1.CLEANING THE COIL AIR SIDE5. GASKETS/SEALING MATERIALS D.HOUSE AIR BLOWERVIII. TROUBLESHOOTING FILTER MAINTENANCE PROCEDUREFILTER REPLACEMENT DIAGNOSTIC FEATURESThe LED will also flash once at power-up TROUBLESHOOTING GUIDE AT THE INTEGRATED CONTROL? Yes AFTER GAS VALVE OPENS, DO THE BURNERS IGNITE? DOES SYSTEM RUN UNTIL THERMOSTAT IS SATISFIED? IF LED LIGHT FLASHES APPENDIX – A REPLACEMENT PARTS Page APPENDIX – B WIRING DIAGRAM