DOWN FLOW & DIRECT VENT SEALED COMBUSTION
INSTALLATION AND SERVICE MANUAL
FOR YOUR SAFETY
GAS FIRED HIGH EFFICIENCY FURNACE
SECTION
TABLE OF CONTENTS
I. SAFETY INFORMATION
Page
Page
The vent and air intake elbows must be kept away from bushes, shrubs or any vegetation that may restrict the flow of flue products. It must also be kept clear of any leaves, weeds or other combustible materials. Keep the vent hood clear of snow. Avoid locating the terminals in areas where standing water or condensate drippage may be a problem
1.A windows be opened
GAS SUPPLY PRESSURE
II. FURNACE SPECIFICATIONS - CMA SERIES
DIMENSIONS
MODEL
INSTALLATION PARTS PACKAGE
NON-COMBUSTIBLEMATERIAL
COMBUSTIBLE MATERIAL.” COMBUSTIBLE MATERIAL
Table
IV. GENERAL INSTALLATION A.FURNACE LOCATION
MODELS CMA
Figure 1B
Combustible Floor Base Model: 70-BASE Figure 1A
Coil Cabinet
Cottage Base Model: 01COT-BASE Figure 1C
Figure Figure
B. BASE INSTALLATION
1. Combustible Floor Base Model: 70 BASE
Figure
C. ALCOVE INSTALLATION
2. Cottage Base Model: 01COT BASE
Figure
D. CLOSET INSTALLATION
E. FUEL PIPING
F.GENERAL VENTING REQUIREMENTS
Table
MAXIMUM VENT LENGTH
Figure 6. CMA*-75SHOWN
1. Vent And Combustion Air Pipes
H. Direct Venting Through a Sidewall
2. Exhaust Vent Termination Elbow
Sidewall Venting
Page
4. Vent Terminal Location Guidelines
Terminations
Figure Figure
5.Secure plate to roof
Figure K.CONDENSATE DRAIN LINE AND TRAP ASSEMBLY
1. Electrical Branch Supply Circuit
Figure L.ELECTRICAL WIRING
2.Connection Of Power Supply Wires
3.Connection Of Room Thermostat Wires
Electrical Wire Diameter AWG 24 22 20 18
4. BLOWER MOTOR SPEED WIRING Figure
Pressure
CMA1-50
Speed Tap \
Static
Pressure
CMA2-75
Speed Tap \
Static
5. FIELD WIRING AND REPLACING WIRING
V.STARTING THE UNIT A. SEQUENCE OF OPERATIONS
MAIN BURNER OPERATION CALL FOR HEAT SATISFIED
OPERATING INSTRUCTIONS
B.INITIAL START UP
C.ADJUSTMENT OF BTU INPUT RATE
D.BURNER ADJUSTMENT
GAS PRESSURE CHART FOR CMA* MODEL FURNACES
Figure
E.SETTING TEMPERATURE RISE
F.FURNACE CHECKOUT PROCEDURE
VII. DEALER MAINTENANCE
VI. INSTALLERS INSTRUCTIONS TO USER
B.GENERAL INSPECTION
2.CONDENSATE LINE/TRAP ASSEMBLY
4. INDUCER BLOWER ASSEMBLY
A.ELECTRICAL
D.HOUSE AIR BLOWER
1.CLEANING THE COIL AIR SIDE
5. GASKETS/SEALING MATERIALS
C.HEAT EXCHANGER
DIAGNOSTIC FEATURES
FILTER MAINTENANCE PROCEDURE
FILTER REPLACEMENT
VIII. TROUBLESHOOTING
The LED will also flash once at power-up
TROUBLESHOOTING GUIDE
AT THE INTEGRATED CONTROL?
Yes AFTER GAS VALVE OPENS, DO THE BURNERS IGNITE?
DOES SYSTEM RUN UNTIL THERMOSTAT IS SATISFIED?
IF LED LIGHT FLASHES
APPENDIX – A REPLACEMENT PARTS
Page
APPENDIX – B WIRING DIAGRAM
Related pages
Troubleshooting for JVC KD-SX980
Specifications for Desa (V)T36NA
Water Full Indicator Light RED for Danby 7009REE
G0651 Wiring Diagram 220V, 1-Ph for Grizzly G0651
HOW to Connect Water Supply Hose for Samsung SW62ASP
Installing the StorPoint CD in a Tower for Axis Communications CD E100
Stand & Panels Parts List SB1042PF-43PF, SB1059F-61PF for Southbend SB1042PF
Language Code List for Samsung HT-Q9R/ELS
Appendix D Specifications for Linksys SRW224P
Where can I find troubleshooting tips in the
Dell 1610HD manual
?
Top
Page
Image
Contents