II. FURNACE SPECIFICATIONS - CMA SERIES

MODEL

CMA1-50

 

 

 

CMA2-75

INPUT IN BTUH

50,000

 

 

 

75,000

OUTPUT IN BTUH

48,000

 

#42

 

72,000

MAIN ORIFICE-NAT.

 

 

 

 

MAIN ORIFICE-LP

 

 

1.5 mm

 

 

GAS SUPPLY PRESSURE

 

11” IN.W.C.

 

L.P. MINIMUM

 

 

NAT. MINIMUM

 

4.5”IN.W.C.

 

L.P. MAXIMUM

 

14” IN.W.C.

 

NAT. MAXIMUM

 

14” IN.W.C.

 

GAS MANIFOLD PRESSURE

 

10.0” + .03 IN.W.C.

 

L.P.

 

 

NAT.

 

3.5” + .03 IN. W.C.

 

INTAKE SIZE IN INCHES

 

 

2”

 

 

VENT SIZE IN INCHES

 

 

2”

 

 

NOMINAL TEMPERATURE RISE

 

 

55°F

 

 

SEASONAL EFFICIENCY (AFUE*)

 

 

95%

 

 

*ANNUAL FUEL UTILIZATION EFFICIENCY

 

 

 

 

 

DIMENSIONS

WIDTH 18” DEPTH 25-3/4" HEIGHT 57"

CABINET SIZE

SUPPLY AIR OUTLET

 

WIDTH 12” DEPTH 12"

 

ELECTRICAL SUPPLY

 

115 VOLTS-- 60HZ --1/PH

 

FUSE OR HACR BREAKER

 

 

15 AMPS

 

 

TOTAL CURRENT AMPS

 

7.15 AMPS

 

NOMINAL ANTICIPATOR SETTING

 

0.8 MILLIAMPS

 

FILTER SIZE

 

(1) 18” X 24” X 1”

 

APPROXIMATE SHIPPING WEIGHT

 

 

175 LBS.

 

 

BLOWER DATA

 

12-9T DIRECT DRIVE

 

BLOWER MODEL

 

 

MOTOR HORSEPOWER

 

 

1/2

 

 

MOTOR RPM

 

1065 (HIGH SPEED)

 

CFM @ .2 & .5 IN. W.C. SPEED

.2”

.5”

.2”

.5”

LOW

805

695

797

668

MD-LOW

1010

860

995

869

MD-HIGH

1196

1038

1210

1076

HIGH

1338

1162

1420

1259

FOR BURNER COMBUSTION INFORMATION REFER TO INITIAL STARTUP.

6

Image 8
Contents INSTALLATION AND SERVICE MANUAL FOR YOUR SAFETYGAS FIRED HIGH EFFICIENCY FURNACE DOWN FLOW & DIRECT VENT SEALED COMBUSTIONTABLE OF CONTENTS SECTIONI. SAFETY INFORMATION Page Page The vent and air intake elbows must be kept away from bushes, shrubs or any vegetation that may restrict the flow of flue products. It must also be kept clear of any leaves, weeds or other combustible materials. Keep the vent hood clear of snow. Avoid locating the terminals in areas where standing water or condensate drippage may be a problem 1.A windows be opened II. FURNACE SPECIFICATIONS - CMA SERIES DIMENSIONSMODEL GAS SUPPLY PRESSUREINSTALLATION PARTS PACKAGE COMBUSTIBLE MATERIAL.” COMBUSTIBLE MATERIAL NON-COMBUSTIBLEMATERIALTable IV. GENERAL INSTALLATION A.FURNACE LOCATIONMODELS CMA Figure 1B Combustible Floor Base Model: 70-BASE Figure 1ACoil Cabinet Cottage Base Model: 01COT-BASE Figure 1C Figure Figure B. BASE INSTALLATION1. Combustible Floor Base Model: 70 BASE Figure C. ALCOVE INSTALLATION2. Cottage Base Model: 01COT BASE D. CLOSET INSTALLATION FigureE. FUEL PIPING F.GENERAL VENTING REQUIREMENTS MAXIMUM VENT LENGTH TableFigure 6. CMA*-75SHOWN H. Direct Venting Through a Sidewall 1. Vent And Combustion Air Pipes2. Exhaust Vent Termination Elbow Sidewall Venting Page 4. Vent Terminal Location Guidelines Terminations 5.Secure plate to roof Figure FigureFigure K.CONDENSATE DRAIN LINE AND TRAP ASSEMBLY Figure L.ELECTRICAL WIRING 2.Connection Of Power Supply Wires3.Connection Of Room Thermostat Wires 1. Electrical Branch Supply CircuitElectrical Wire Diameter AWG 24 22 20 18 4. BLOWER MOTOR SPEED WIRING Figure CMA1-50 Speed Tap \Static PressureCMA2-75 Speed Tap \Static Pressure5. FIELD WIRING AND REPLACING WIRING V.STARTING THE UNIT A. SEQUENCE OF OPERATIONS MAIN BURNER OPERATION CALL FOR HEAT SATISFIED B.INITIAL START UP OPERATING INSTRUCTIONSC.ADJUSTMENT OF BTU INPUT RATE GAS PRESSURE CHART FOR CMA* MODEL FURNACES D.BURNER ADJUSTMENTE.SETTING TEMPERATURE RISE FigureF.FURNACE CHECKOUT PROCEDURE VI. INSTALLERS INSTRUCTIONS TO USER VII. DEALER MAINTENANCE2.CONDENSATE LINE/TRAP ASSEMBLY 4. INDUCER BLOWER ASSEMBLYA.ELECTRICAL B.GENERAL INSPECTION1.CLEANING THE COIL AIR SIDE 5. GASKETS/SEALING MATERIALSC.HEAT EXCHANGER D.HOUSE AIR BLOWERFILTER MAINTENANCE PROCEDURE FILTER REPLACEMENTVIII. TROUBLESHOOTING DIAGNOSTIC FEATURESThe LED will also flash once at power-up TROUBLESHOOTING GUIDE AT THE INTEGRATED CONTROL? Yes AFTER GAS VALVE OPENS, DO THE BURNERS IGNITE? DOES SYSTEM RUN UNTIL THERMOSTAT IS SATISFIED? IF LED LIGHT FLASHES APPENDIX – A REPLACEMENT PARTS Page APPENDIX – B WIRING DIAGRAM