All installations and services must be performed by qualified service personnel.
II. FURNACE SPECIFICATIONS - CMA SERIES
MODEL |
|
|
| ||
INPUT IN BTUH | 50,000 |
|
|
| 75,000 |
OUTPUT IN BTUH | 48,000 |
| #42 |
| 72,000 |
MAIN |
|
|
|
| |
MAIN |
|
| 1.5 mm |
|
|
GAS SUPPLY PRESSURE |
| 11” IN.W.C. |
| ||
L.P. MINIMUM |
|
| |||
NAT. MINIMUM |
| 4.5”IN.W.C. |
| ||
L.P. MAXIMUM |
| 14” IN.W.C. |
| ||
NAT. MAXIMUM |
| 14” IN.W.C. |
| ||
GAS MANIFOLD PRESSURE |
| 10.0” + .03 IN.W.C. |
| ||
L.P. |
|
| |||
NAT. |
| 3.5” + .03 IN. W.C. |
| ||
INTAKE SIZE IN INCHES |
|
| 2” |
|
|
VENT SIZE IN INCHES |
|
| 2” |
|
|
NOMINAL TEMPERATURE RISE |
|
| 55°F |
|
|
SEASONAL EFFICIENCY (AFUE*) |
|
| 95% |
|
|
*ANNUAL FUEL UTILIZATION EFFICIENCY |
|
|
|
|
|
DIMENSIONS | WIDTH 18” DEPTH | ||||
CABINET SIZE | |||||
SUPPLY AIR OUTLET |
| WIDTH 12” DEPTH 12" |
| ||
ELECTRICAL SUPPLY |
| 115 |
| ||
FUSE OR HACR BREAKER |
|
| 15 AMPS |
|
|
TOTAL CURRENT AMPS |
| 7.15 AMPS |
| ||
NOMINAL ANTICIPATOR SETTING |
| 0.8 MILLIAMPS |
| ||
FILTER SIZE |
| (1) 18” X 24” X 1” |
| ||
APPROXIMATE SHIPPING WEIGHT |
|
| 175 LBS. |
|
|
BLOWER DATA |
|
| |||
BLOWER MODEL |
|
| |||
MOTOR HORSEPOWER |
|
| 1/2 |
|
|
MOTOR RPM |
| 1065 (HIGH SPEED) |
| ||
CFM @ .2 & .5 IN. W.C. SPEED | .2” | .5” | .2” | .5” | |
LOW | 805 | 695 | 797 | 668 | |
1010 | 860 | 995 | 869 | ||
1196 | 1038 | 1210 | 1076 | ||
HIGH | 1338 | 1162 | 1420 | 1259 |
FOR BURNER COMBUSTION INFORMATION REFER TO INITIAL STARTUP.