HP Smart Array Advanced Pack Software manual Battery pack LEDs, Amber Green Interpretation

Page 28

1 - Amber

2 - Green

3 - Green

Interpretation

 

 

 

 

Flashing 1 Hz

On

Off

An overtemperature condition exists.

Flashing 2 Hz

Flashing 2 Hz

Off

The capacitor pack is not attached.

Flashing 2 Hz

Flashing 2 Hz

On

The capacitor has been charging for 10 minutes, but

 

 

 

has not reached sufficient charge to perform a full

 

 

 

backup.

 

 

 

 

On

On

Off

The current backup is complete, but power fluctuations

 

 

 

occurred during the backup.

On

On

On

The cache module microcontroller has failed.

Battery pack LEDs

Item

Color

Description

 

 

 

1

Green

System Power LED. This LED is on when the system is

 

 

powered up and 12 V system power is available. This

 

 

power supply is used to maintain the battery charge and

 

 

provide supplementary power to the cache microcontroller.

 

 

 

2

Green

Auxiliary Power LED. This LED is on when 3.3V auxiliary

 

 

voltage is detected. The auxiliary voltage is used to

 

 

preserve BBWC data and is available any time that the

 

 

system power cords are connected to a power supply.

 

 

 

3

Amber

Battery Health LED. To interpret the illumination patterns of

 

 

this LED, see the following table.

 

 

 

4

Green

BBWC Status LED. To interpret the illumination patterns of

 

 

this LED, see the following table.

 

 

 

Component identification 28

Image 28
Contents Abstract Part Number August EditionPage Contents Installation and configuration Regulatory compliance notices Moving drives and arrays Adding drivesComponent identification Controller componentsP212 components DescriptionP222 components P400 components model with front connectorsFor LED locations and status, see P222 LEDs on Description P400 components model with back connectors P410 components P411 componentsP420 components For LED locations and status, see P420 LEDs on DescriptionE500 components P421 componentsFor LED locations and status, see P421 LEDs on Description P700m components P711m components P712m componentsP800 components P721m componentsFor LED locations and status, see P721m LEDs on P812 components Controller board runtime LEDs P822 componentsP212, P410, and P411 LEDs Color Name CommentsE500 and P400 LEDs Idle Task LED status Controller CPU activity levelP420 LEDs P222 LEDsColor Name Interpretation P421 LEDs P700m LEDs Green CR8 Idle TaskP711m LED P712m LEDP721m LEDs P800 LEDsCannot function due to an internal problem. If P812 LEDs P822 LEDs Fbwc module LEDsFbwc module LEDs P410, P411, P711m, P812 Fbwc module LEDs P222, P420, P421, P721m, P822 Green LED Amber LED InterpretationAmber Green Interpretation Battery pack LEDsColor Description LED3 pattern LED4 pattern Interpretation Specifications Memory and storage capacity conventionsRAID conventions Smart Array Advanced PackSupported servers and server blades Required hardwareSpecifications common to all controller models Feature DetailsController Speed Supported product Server RulesE500, P411, and P421 specifications Controller specifications by modelSpecification E500 P411 P421 P400, P410, and P420 specifications P212 and P222 specificationsSpecification P400 P410 P420 Specification P212 P222P700m, P711m, P712m, and P721m specifications P800, P812, and P822 specificationsSpecification P700m P711m P712M P721m Specification P800 P812 P822Battery pack service life Procedures for controllers in a server Installation and configurationInstalling a stand-up controller in an unconfigured server Installing the controller board Connecting internal storage Procedures for controllers in a server blade SAS cable part numbersInstallation and configuration Installing the mezzanine controller board Configuration tools Option ROM Configuration for ArraysArray configuration tools ROM-Based Setup UtilityInstalling device drivers System maintenance toolsUpdating firmware Installing Management Agents Diagnostic toolsEvent Notification Service HP Insight Diagnostics Installation and configuration Upgrade and replacement procedures Replacing the battery on the P212, P410, and P411 modelsReplacing the Fbwc module on the P410 and P411 models Replacing the Bbwc module on the P212, P410, and P411 models Upgrade and replacement procedures Upgrade and replacement procedures Installing an E500 or P400 cache battery Replacing an E500 or P400 cache battery Replacing the E500 or P400 cache Replacing the P700m cache battery Upgrade and replacement procedures Upgrade and replacement procedures Removing a P711m capacitor pack Replacing a P711m cache module Upgrade and replacement procedures Upgrade and replacement procedures Replacing a P712m cache module Replacing the Fbwc module on the P721m Replacing a P800 cache battery Upgrade and replacement procedures Upgrade and replacement procedures Upgrade and replacement procedures Upgrade and replacement procedures Replacing the P800 cache module or controller Upgrade and replacement procedures Upgrade and replacement procedures Replacing a P812 cache module Upgrade and replacement procedures Upgrade and replacement procedures Upgrade and replacement procedures Replacing a P822 cache module Upgrade and replacement procedures Drive procedures Identifying the status of a legacy driveIdentifying the status of an HP SmartDrive Status DefinitionRecognizing drive failure Effects of a drive failureRecovering from compromised fault tolerance Compromised fault toleranceReplacing drives Automatic data recovery rebuild Before replacing drivesTime required for a rebuild Abnormal termination of a rebuild Moving drives and arrays Restore data from backupUpgrading drive capacity Adding drives Drive procedures Preventing electrostatic discharge Electrostatic dischargeGrounding methods to prevent electrostatic discharge Regulatory compliance notices Federal Communications Commission noticeFCC rating label FCC Notice, Class a EquipmentCables ModificationsCanadian notice Avis Canadien European Union regulatory notice Bsmi noticeBattery replacement notice Chinese noticeJapanese notice Korean notice Class a equipmentTaiwan battery recycling notice Acronyms and abbreviations HP Service Pack for ProLiant System Management HomepageDocumentation feedback Index CpqonlinFederal Communications Commission FCC Smart Array Advanced Pack Saap