CAUTION: The cache module connector does not use the
1.Update the controller firmware. See "Updating firmware (on page 45)."
2.Close all applications.
3.Power down the server.
4.Disconnect the power cord from the AC power source.
5.Disconnect the power cord from the server.
6.Remove or open the access panel.
7.If the existing cache module is connected to a capacitor pack, observe the FBWC module LEDs (on page 26):
o If a backup is in progress, wait for the backup to complete.
o If the backup is complete, or if the cache has failed, remove the controller from the server, and then continue with the next step.
8.If access to the cache module is restricted, remove the controller.
9.Open the ejector latches on each side of the DIMM slot. Normally, the cache module is ejected from the DIMM slot. If the module is not ejected automatically, remove the cache module.
CAUTION: When connecting or disconnecting the capacitor pack cable, the connectors on the cache module and cable are susceptible to damage. Avoid excessive force and use caution to avoid damage to these connectors.