6 Enclosure monitor performance and scalability guidelines
NOTE: This appendix describes general performance and scalability guidelines for monitoring HP BladeSystem
The HP BladeSystem Management Pack processes state monitoring and alert rules within the Operations Manager agent, and it includes the HP BladeSystem Enclosure Monitor Service to perform primary enclosure monitoring. The monitor service communicates to the Onboard Administrator of each registered HP BladeSystem enclosure through a SOAP transport and listens to SNMP traps from the OA in
The monitor service requires system and network resources that are shared with the Operations Manager server or other applications on the system where it is configured. As the number of enclosures in an Operations Manager domain increases, resource utilization by the monitor service may also increase.
This information describes performance characteristics and scalability options for the monitor service and recommends hardware configurations for typical scenarios. Because your specific scenario may differ from these guidelines, key factors influencing performance are presented so that you can adapt the information in this guide to your specific requirements.
Hardware and software configuration guidelines
These guidelines are based on specific hardware and software configurations. If your hardware and software configurations differ, the recommended hardware may not adequately address your needs. As a starting point, it is recommend that:
•The Operations Manager agent and Operations Manager server are on a
•The HP BladeSystem Enclosure Monitor Services and HP Onboard Administrators are on a
Capacity planning guidelines and best practices
The HP BladeSystem Enclosure Monitor Service monitors multiple enclosures simultaneously with a secured HTTPS/SOAP connection to each HP Onboard Administrator. The monitor service establishes an HTTPS connection for each enclosure that has been registered through the HP BladeSystem Enclosure Monitor Manager. Each connection goes through the following phases:
1.
2.Data
3.
4.Data
The connection phase and data collection phase occur once in a connection. The data collection phase (phase 2) is the busiest phase and uses a significant amount of system and network resources. After the data collection is completed, the management pack can access all enclosure data to produce inventory and state information. The monitor service spends most of the time in the monitoring phase listening to the network heartbeat from the HP Onboard Administrator and watching for any information change to the monitored enclosure. If a change is found, the data recollection phase starts and will collect partial data only where a change is reported. After the data recollection is completed, the monitor service continues the monitoring phase.
40 Enclosure monitor performance and scalability guidelines