Configuring HP FTAM/9000
Additional Configuration Parameters
ae_max_active_assoc This parameter sets the number of connections an FTAM application is allowed to have established at any one time. This parameter is important for FTAM applications that use low level context sensitive functions and maintain multiple connections at any one time.
FORMAT | decimal number |
UNIT | connections/associations |
RANGE | 1 - 50 |
DEFAULT | 20 |
OSICONF | yes |
DYNAMIC | yes |
SCREEN | View/Modify FTAM Initiator |
FIELD | Maximum Number of |
| Associations/Invocation |
ae_objid This object ID may optionally be sent by an application or service during connection establishment, and may be used for security or authentication purposes by
FORMAT | ASCII string |
UNIT | NA |
RANGE | Elements of the object ID are separated by |
| periods. For example, 2.5.4.29 |
42 | Chapter 2 |