Restarted Migration Showed Incorrect FAILED Status
Problem: If a migration failed and it has been restarted using the HP 3PAR Online Import Utility startmigration command again, the status will immediately change to IMPORTING. However, due to timing issues, the status may change back to FAILED for a short time before returning to
IMPORTING.
Solution: On a restarted migration, if an HP 3PAR Online Import Utility showmigration command shows FAILED status unexpectedly, wait
Migration Includes Unexpected LUNs and Hosts
Problem: When the
Workaround:
Masking View Required for Offline Migration of LUN with No Host
Problem: If you are migrating a LUN without a host, it still needs to be in a masking view in order to be successfully migrated.
Workaround: The LUN must be added to a storage group and the storage group must be part of a masking view on the EMC VMAX Storage system.
HP 3PAR Online Import Utility for EMC Storage does not distinguish between source arrays when managing same host
Problem: The
This problem occurs when OIU asks
Workaround: The
Troubleshooting Issues 101