The migration process selects objects to migrate using the following rules:

Host—When selecting a single host or group of hosts with volume presentations, all the volumes presented to the host(s) are migrated. In addition, any presentations the source volumes have to other hosts will include those hosts and all of their presented volumes in the migration.

Presented volumes—When selecting a volume or group of volumes with host presentations, the selected volumes and the hosts to which they are presented are migrated. In addition, any presentations the source hosts have with other volumes will include those volumes in the migration.

Unpresented volumes—Only the selected unpresented volumes are migrated. The offline migration type is the only type available for unpresented volume migration.

NOTE: For more information about supported and unsupported configurations and about the implicit selection of objects for migration, see “Migrations Supported by HP 3PAR Online Import Utility for EMC Storage” (page 24).

EMC to HP 3PAR Migration Process

The process to migrate EMC Storage volumes to HP 3PAR StoreServ Storage system consists of three parts:

Premigration—Work done to define the source and destination storage system to a migration definition. This work is not repeated when migrating a second host or additional volumes after a first migration.

Migration—Creating and executing the migration. Migration includes the process of unzoning the destination storage system from the source storage system and removing the source storage system after the migration is complete. This work is repeated for every migration.

Post-migration—Removal of the online import setup.

8Overview of HP 3PAR Online Import for EMC Storage

Image 8
Contents HP 3PAR Online Import for EMC Storage Data Migration Guide AbstractPage Contents Performing MDM Using a Windows Host Performing MDM Using a Linux HostPerforming MDM Using a Hyper-V Host Performing Offline Data MigrationTroubleshooting Support and Other Resources 102 Documentation feedback 106 Glossary 107 Index 108Understanding Which Data is Migrated Overview of HP 3PAR Online Import for EMC StorageTypes of Data Migration EMC to HP 3PAR Migration Process Migration Process Checklists Prerequisite Component InstallationOnline Migration PremigrationMigration checklist-Online Post-migration checklist-OnlineMigration Post-MigrationMinimally Disruptive Migration Prerequisite component installation-MDMPremigration checklist-MDM Migration checklist-MDM Post-migration checklist-MDMPrerequisite component installation-offline Offline MigrationPremigration checklist-offline Migration checklist-offlinePost-migration checklist-offline Installation and Setup for Data Migration Installing EMC SMI-S ProviderConfiguring EMC SMI-S Provider \Program Files\EMC\ECIM\ECOM\binInstalling the HP 3PAR Online Import Utility for EMC Storage Default Log File Name \Program Files x86\Hewlett-Packard\hp3paremcoiuWhen the Welcome screen appears, click Next Installation and Setup for Data Migration Install location\Hewlett-Packard\ hp3paremcoiu\CLI Installation and Setup for Data Migration Installing the HP 3PAR Online Import Utility for EMC Storage Installation and Setup for Data Migration Migrations Supported for VNX, CLARiiON CX4, and Vmax Migration supported by the HP 3PAR Online Import UtilityMigration supported by the HP 3PAR Online Import Utility Migration supported by the HP 3PAR Online Import Utility Migration supported by the HP 3PAR Online Import Utility Unsupported Configuration General Considerations Preparing for Data MigrationData Migration Considerations Planning for Migration Reconfiguring the Host DSMSystem Requirements Network and Fabric Zoning Requirements Multipathing software by operating systemPremigration Steps Data migration zoningSymaccess -sid vmax id list logins Preparing the Host for MDMIdentifying the Source and Destination Storage Systems Preparing Windows Clusters for MigrationExample 1 addsource command Example 2 showsource commandExample 4 Certificate validation error Example 6 showdestination commandCreating the Data Migration Task OIUmigrationIDSGOIUmigrationIDMV OIUmigrationIDIGOIUmigrationIDPG MDM Performing Online Data Migration Using Linux Online Data Migration with Removal of EMC PowerPathExample 9 Updating the multipath.conf file Example 10 Using createmigration with -migtype online Migtype online optionExample 11 Updating path configuration on the host Example 12 Unzoning an Rhel 5.x host from the source array Example 13 Unzoning an Rhel 6.x host from the source arrayExample 14 Removing a path to a storage device in Rhel Online Data Migration with Native device-mapper MultipathViewing Migration Status Vmax Example 19 Using createmigration with -migtype online Example 18 Updating the multipath.conf fileExample 20 Updating path configuration on the host Example 21 Unzoning an Rhel 5.x host from the source array Example 22 Unzoning an Rhel 6.x host from the source arrayExample 23 Removing a path to a storage device in Rhel Performing MDM Using a Windows Host Required InformationCreating the Data Migration Task Source storage systemExample 27 showmigrationdetails command Example 25 createmigration commandExample 26 showmigration command For Windows Server 2003 or Windows Server 2003 R2 Example 29 showmigration command Bringing the Windows Host Back OnlineExample 30 Unsafe to bring the host online Example 31 Safe to bring the host onlinePerforming Subsequent Migrations Viewing Migration StatusAborting a Migration Performing MDM Using a Linux Host Example 34 showmigrationdetails command Example 32 createmigration commandExample 33 showmigration command Performing MDM Using a Linux Host Example 36 showmigration command Bringing the Linux Host Back OnlineExample 37 Unsafe to bring the host online Example 38 Safe to bring the host onlineExample 40 Linux Host with Multiple LUNs Performing MDM Using a Hyper-V Host Example 43 showmigrationdetails command Example 41 createmigration commandExample 42 showmigration command Example 45 showmigration command Example 47 Safe to bring the host online Bringing the Hyper-V Host Back OnlineExample 46 Unsafe to bring the host online Performing Subsequent Migrations Performing Offline Data Migration Prerequisites Required InformationIdentifying the Source Storage System Identifying the Destination Storage SystemExample 51 showdestination command Example 52 createmigration commandExample 53 showmigration command Example 54 showmigrationdetails commandExample 56 showmigration command Performing Post-Migration TasksExample 57 Removing the Storage System Removing a Storage System from EMC SMI-S ProviderClarStorageSystem Removing a Storage System from EMC SMI-S Provider 11 HP 3PAR Online Import Utility for EMC Storage Commands AdddestinationAddsource VmaxExample Volume device id CreatemigrationSourcevolume Destinationvolume Taskid Progress Installcertificate HelpRemovedestination Source OptionalShowconnection RemovemigrationRemovesource Showdestination DescriptionShowmigration ShowdestinationShowmigrationdetails ShowmigrationShowsource StartmigrationStartmigration -migrationid Troubleshooting HP 3PAR Online Import Utility Service HP 3PAR Online Import Utility Server Logs and OutputExample 59 dv command Example 60 eq commandEMC SMI-S Provider Server Logs and Output Increasing the EMC SMI-S Provider Server Logging LevelWindows C\Program Files\EMC\ECIM\ECOM\conf\Portsettings.xml TestSmiProvider Login and Command Examples with Output Example 61 Output on WindowsExample 62 dv command output Localhost5988 ? dvExample 63 eq command output InstanceHP 3PAR Online Import Utility for EMC Storage Error Messages Troubleshooting Issues Not able to add a source EMC Storage systemNot able to create migration Example 64 createmigration command errorExample 65 OIU login error Error Logging into the HP 3PAR Online Import Utility CLI HP 3PAR Online Import Utility addsource Error OIUERRDST0004 Example 66 Example error Example 67 Error message-example \InFormMC\security\Program Files x86\Hewlett-Packard\hp3paremcoiu\bin TPDCertVerifier.batError when Importing LUN of Size Smaller than 256 MB Example 68 Error message-exampleRestarted Migration Showed Incorrect Failed Status Migration Includes Unexpected LUNs and HostsHP 3PAR documentation Support and Other ResourcesContacting HP HP 3PAR Command Line Interface Administrator’s Storage Physical Planning Typographic conventions HP 3PAR branding informationRequired Document conventionsDocumentation feedback Glossary DSMIndex SMI-S Provider configuring Windows Source storage system identifying