Table 9 Prerequisite component installation—offline (continued)
Number | Step | See |
|
| See also “Configuration Rules for HP 3PAR Online |
|
| Import for EMC Storage Support” (page 15) |
2 | Install EMC | “Installing EMC |
3 | Install the HP 3PAR Online Import Utility. | “Installing the HP 3PAR Online Import Utility for |
|
| EMC Storage” (page 17) |
Premigration
Table 10 Premigration checklist—offline
Number Step
1Zone EMC Storage systems and HP 3PAR StoreServ Storage systems as peers.
See
“Zoning the Source EMC Storage to the Destination HP 3PAR StoreServ Storage System” (page 33)
2 | Stop all server applications; offline/unmount | “Preparing Host for Migration” (page 66) |
| LUNs. |
|
3 | Zone the host and the HP 3PAR StoreServ Storage | “Zoning the Host to the Destination HP 3PAR |
| system; then shut down the host. | StoreServ Storage System” (page 66) |
4 | Add source and destination storage systems (HP | “Identifying the Source and Destination Storage |
| 3PAR Online Import Utility: addsource and | Systems” (page 66) |
| adddestination commands). |
|
5Create migration (HP 3PAR Online Import Utility: “Creating the Data Migration Task” (page 68) createmigration command)
Migration
Table 11 Migration checklist—offline
Number Step
1Start the migration (HP 3PAR Online Import Utility: startmigration command)
See
“Starting the Data Migration from Source EMC Storage System to Destination HP 3PAR StoreServ Storage System” (page 69)
2 | Monitor migration with the HP 3PAR Online | “Viewing Migration Status” (page 55) |
| Import Utility until completion. |
|
3 | Optional: Remove the migration definition when | “removemigration” (page 80) |
| the migration has completed. |
|
Offline Migration 13