HP manual Specifications, T1000 physical specifications, T1500 physical specifications

Page 31

Specifications

In this section

 

 

T1000 physical specifications

31

T1500 physical specifications

31

UPS input specifications

31

T1000 output specifications

32

T1500 output specifications

32

T1000 power protection specifications

32

T1500 power protection specifications

32

Voltage specifications

32

Output tolerance specifications

33

Output feature specifications

33

Battery specifications

33

Battery runtime

33

Environmental specifications

33

T1000 physical specifications

 

Parameter

Value

 

Height

26.2 cm (10.3 in)

 

Depth

33.8 cm (13.3 in)

 

Width

17.0 cm (6.7 in)

 

Weight

15.9 kg (35 lb)

 

T1500 physical specifications

 

Parameter

Value

 

Height

26.2 cm (10.3 in)

 

Depth

33.8 cm (13.3 in)

 

Width

17.0 cm (6.7 in)

 

Weight

20.3 kg (44.8 lb)

 

UPS input specifications

NOTE: An asterisk (*) indicates the default setting.

Specifications 31

Image 31
Contents HP UPS T1000/1500 User Guide Audience assumptions Contents Spares Index UPS front panel Component identificationThis section UPS front panel controls and LED indicators UPS T1000 NA/JPN/TWN rear panel UPS T1500 NA/JPN/TWN rear panel UPS T1000 Intl rear panel UPS T1500 Intl rear panel Precautions InstallationElectrical requirements Connecting the batteries Checking the battery recharge dateSelecting the UPS voltage configuration Connecting the serial communications port Connecting the host computerConnecting the USB communications port Connecting the Network Transient ProtectorsConnecting devices to the UPS Connecting the UPS to utility powerCharging the UPS batteries Powering up the UPS UPS operations Silencing an audible alarmPowering down the UPS Audible alarm conditionsUPS operations HP Power Manager features Power managementUpdating the UPS firmware Replacing the batteries MaintenanceImportant battery safety information Battery care and storage guidelinesUPS battery replacement procedure Disconnect the negative black lead Remove the battery module Cleaning battery spills Maintenance UPS does not start TroubleshootingAudible alarm sounds UPS operates on battery onlyVoltage Configuration LED is green UPS frequently switches between utility and battery powerUPS does not provide the expected backup time Power LED flashesOutput Load Level LED is red or flashing red Battery Charge LED is redBattery Warning LED is amber Site Wiring Fault LED is redUPS input specifications SpecificationsT1000 physical specifications T1500 physical specificationsT1500 power protection specifications T1000 output specificationsT1500 output specifications T1000 power protection specificationsBattery runtime Output tolerance specificationsOutput feature specifications Battery specificationsPage Ordering spares T1000 UPS spare parts listT1500 UPS spare parts list SparesBefore you contact HP Technical supportHP contact information Pre-Failure Battery Warranty Warranty informationLimited warranty $250,000 Computer Load Protection GuaranteeNotification from power management software FCC rating label Regulatory compliance noticesRegulatory compliance identification numbers Federal Communications Commission noticeClass B equipment Class a equipmentEuropean Union regulatory notice ModificationsCables Canadian notice Avis CanadienJapanese notice Bsmi notice Power cord statement for Japan Battery replacement noticeKorean notice Preventing electrostatic discharge Electrostatic dischargeGrounding methods to prevent electrostatic discharge Acronyms and abbreviations Index Index Index