Use a terminal emulation program to access the HP UPS Management Module Service Menu:

1.Be sure that you have connected the configuration cable ("Connecting the configuration cable" on page 21) to the management module and the host computer.

2.Launch a terminal emulation program, such as HyperTerminal ("Launching a terminal emulation program" on page 21).

3.On the session screen, the POST executes, and then a prompt appears. Press any key within 5 seconds to enter the HP UPS Management Module Service Menu.

For more information about the POST, see "POST (on page 79)."

For more information about the Service Menu, see "Service Menu (on page 80)."

POST

When the card is powered up or reset, the bootloader will perform a POST and output the following text:

RAM test:PASS

DMA memory-to-memory test: PASS

IRQ test:

PASS

Ethernet loopback test:

PASS

Serial loopback test:

PASS

HP UPS Management Module

NETWORK INTERFACE PARAMETERS:

IP address: 173.173.173.150

Subnet mask: 255.255.0.0

Default gateway: 169.254.1.254

HARDWARE PARAMETERS:

Module Serial number: CN85SK000M

MAC address: 00:13:21:C6:1C:BC

Copyright (C) 2006 Hewlett-Packard Development Company, L.P.

Press any key in 5 seconds to enter the Service menu.

If any error is detected in the boot process, the Error LED illuminates or flashes (on page 89).

Navigating the menus

After you have successfully initiated a terminal emulation or telnet session, the HP UPS Management Module Service Menu appears.

Open a submenu by entering the corresponding option number at the prompt.

To enter or change configuration information, follow the onscreen prompts.

Enter 0 at the submenu prompt to go to the previous menu. -or-

Enter 0 at the Main menu prompt to exit the utility.

HP UPS Management Module Service Menu 79

Image 79
Contents HP UPS Management Module User Guide Audience assumptions Contents HP UPS Management Module web interface Technical support Alert messages 104 Overview FeaturesIntroduction HP UPS Power Protection Agent requirements HP UPS Power Protection Agent overviewTypical hardware configurations Configuration B Configuration aConfiguration C Configuration D Configuration E Configuration F Web interface requirements Configuration GSoftware Browser Front panel Component identificationInstalling the management module Installing the HP UPS Management ModuleRequired tools Installing the HP UPS Management Module Connecting the network cable Checking the Error LEDLaunching a terminal emulation program Connecting the configuration cablePress any key in 5 seconds to enter Service menu Configuring the management module for remote accessConnecting devices Installing the HP UPS Management Module Press the Reset button on the management module front panel Installation overview Installing the HP UPS Power Protection AgentInstalling the agent on Windows operating systems Installing the agent using the GUI method Installing the HP UPS Power Protection Agent Installing the HP UPS Power Protection Agent Installing the HP UPS Power Protection Agent Installing the agent using the silent installation method DevManRA.ini Reconfiguring the agent on Windows operating systemsInstalling the agent using the installation script Installing the agent on Linux operating systemsInstaller launches a separate configuration program Log Installing the agent on SlesInstalling the agent on HP-UX operating systems Reconfiguring the agent on Linux operating systemsInstalling the agent on an Itanium system SetupRA Installing the agent using the silent installation method Uninstalling components from HP-UX systems Reconfiguring the agent on HP-UX operating systemsUninstalling components from Windows systems Uninstalling components from Linux systemsInstalling the HP UPS Power Protection Agent Web browser Accessing the web interfaceHP UPS Management Module web interface HP UPS Management Module web interface overviewSystem tray icon Signing in to the web interfaceBrowser security alert Secure session for Mozilla or SeaMonkey Establishing a secure session for Internet ExplorerEstablishing a secure session for Firefox Navigating the web interfaceOverview menu Home tabNormal Critical HP UPS Management Module web interface Alarms menu Identification menu HP UPS Management Module web interface Parameters menu HP UPS Management Module web interface Manual Control menu Event Log menu Logs tabHP UPS Management Module web interface Application Log menu My Account menu Setup tabUser Accounts menu Network menu Network Management menu System Information tab Snmp Managers tab Trap Receivers tabRemote Access tab Event Notifications menu Events tab Email Setup tab Snmp Traps tab Attached Devices menuUPS Add / Edit Attached Device screen Controlling a load segmentHP UPS Management Module web interface Power Fail menu Advanced power fail settings Shutdown Events menu Low Battery-Selected Low Battery-DeselectedScheduled Shutdowns menu Add/Edit Scheduled Shutdowns screen Help tabAbout menu Info & Updates menu Contents menuTelnet session HP UPS Management Module Service MenuHP UPS Management Module Service Menu overview Accessing the Service MenuTerminal emulation session Navigating the menusHP UPS Management Module Configuration Utility Service MenuUPS Monitor submenu Battery submenu Network Configuration submenuPower Protection submenu Snmp submenu Network Settings submenuWeb Access submenu Remote Console submenuSnmp Traps submenu Emails submenuSession Settings submenu System Configuration submenuDate/Time Configuration submenu Network Time Protocol submenu User Accounts submenuOption number Submenu Description Attached device did not shut down gracefully TroubleshootingAgent does not install on RH Itanium Attached device communication errors appearBrowser incorrectly displays English or Japanese characters Battery Test did not runError LED illuminates or flashes Certificate errorEmail notifications are not received from an HP-UX server Event notifications are not being sent FTP error messages appear when connecting through LinuxFlash update fails over a serial connection Event notification messages do not appear on console screenInstallShield error code -6001 appears during setup HPFlash does not install image.bin on a PentiumInput frequency shows zero Links in traps and emails do not work correctly for Linux Low battery warning is displayedManual Load Dumped alarm not working Invalid IP addressOn boost alarm No powerNon-admin users cannot log in through telnet On battery alarmRedundant UPS status Receiving a security errorSilent install did not execute successfully Sles 10 agent does not autostart after power fail or rebootServers running Windows Server 2003 do not restart Unable to discover a UPS Unable to edit devices using telnetUnable to locate the .INI files for a silent install Task Bar menu does not clearUnable to set event delays using telnet Unable to reboot the machineUnable to start the HP UPS Power Protection Agent for Linux Utility alarm Before you contact HP Technical supportHP contact information Regulatory compliance identification numbers Regulatory compliance noticesFederal Communications Commission notice Canadian notice Avis Canadien ModificationsEuropean Union regulatory notice Japanese notice Bsmi notice Alert messages UPS alarmsAlarm text Description Nominal level Systems Insight Manager overview Systems Insight Manager integrationDiscovering the management module Configuring HP SIM to receive trapsConfiguring the management module to send traps to HP SIM Security considerations overview Security considerationsSnmp monitoring Optional power monitoring using SnmpUpdating the firmware overview Updating the firmwareConfiguring the software for redundancy Redundant configurationRedundant configuration Using the HP UPS Management Upgrade Utility Mass configurationHttps Acronyms and abbreviationsMII Index Linux, installing the agent Secure sessions, Internet Explorer