Sterling SDA 1000-5100 Shipping Info, Unpacking and Inspection, Event of Shipping Damage

Page 2

Shipping Info

Unpacking and Inspection

You should inspect the large dehumidifying dryer for possible shipping damage.

Thoroughly check the equipment for any damage that might have occurred in transit, such as broken or loose wiring and components, loose hardware and mounting screws, etc.

In the Event of Shipping Damage

According to the contract terms and conditions of the Carrier, the responsibility of the Shipper ends at the time and place of shipment.

Notify the transportation company’s local agent if you discover damage.

Hold the damaged goods and packing material for the examining agent’s inspection. Do not return any goods before the transportation company’s inspection and authorization.

File a claim with the transportation company. Substantiate the claim by referring to the agent’s report. A certified copy of our invoice is available upon request. The original Bill of Lading is attached to our original invoice. If the shipment was prepaid, write us for a receipted transportation bill.

Advise customer service regarding your wish for assistance and to obtain an RMA (return material authorization) number.

If the Shipment is Not Complete

Check the packing list as back-ordered items are noted on the packing list. You should have:

;Large Dehumidifying Dryer

;Bill of lading

;Packing list

;Operating and Installation packet

;Electrical schematic and panel layout drawings

;Component instruction manuals

Re-inspect the container and packing material to see if you missed any smaller items during unpacking.

If the Shipment is Not Correct

If the shipment is not what you ordered, contact the shipping department immediately. For shipments in the United States and Canada, call 1 (800) 233-4819; for all other countries, call our international desk at (630) 475-7491. Have the order number and item number available. Hold the items until you receive shipping instructions.

Large Dehumidifying Dryers

ii

Image 2
Contents SDA Large Dehumidifying Dryers With AP0 Controls Event of Shipping Damage Shipping InfoUnpacking and Inspection If the Shipment is Not CompleteCredit Returns Warranty ReturnsReturns Table of Contents Operation Dryer Identification Serial Number Tag Technical Assistance Safety Symbols Used in this Manual SafetyHow to Use This Manual Dryer Safety Tags Description Wear Safety Glasses and Work GlovesOperator Responsibility ResponsibilityGeneral Responsibility Maintenance Responsibility Reporting a Safety Defect General Description Functional DescriptionModels Covered in This Manual Process/Regeneration Cycle Regeneration CycleSequence of Operation Controller Description Controller Screen DescriptionsElectrical Features Standard FeaturesMechanical Features Process Aftercooler OptionsClosed-Loop Regeneration Material Overdrying Protection Recommended Temperature SettingsProcess Air Dust Collector Mechanical Options Electrical OptionsSafety Device Lock-Outs Safety Devices and InterlocksSafety Circuit Standards Fail Safe OperationPage Rigging and Placing Unit Mechanical InstallationUncrating the Equipment Making Electrical ConnectionsChecking for Proper Blower Rotation Checking Blower RotationMaking Dryer/Drying Hopper Process Air Connections Dryer/Drying Hopper Process Air ConnectionsConnecting Aftercooler/Precooler Cooling Water Optional Aftercooler Components & Flow RatesUsing the Drying Hopper Air Trap Drying Hopper Air TrapProcess Air Temperature Controller SwitchesIndicator Lights ControlsIndicator Name Description Lit when Control Output 1 is on. The Out1Lit when Control Output 2 is on. Not used Lights in the Operation Indicator Section whenSetting the Process Air Temperature E5CN Operating ParametersAdjustment Level Indicator Name Description Tuned prior to dryer startupEntering Operating Parameters to Select Modes ON, OFFOptional Setting the High Dew Point AlarmProcess Air Dew Point Display Watlow Operating Parameters Redundant Safety Controller DisplaySetting the Redundant Safety Controller Manf. setting Initial Start-up Auto-Tuning the DryerOperation Pre-Startup ChecksDryer Operation Procedures Page Material Miser OFF Press + to Enable Alarm Display Messages Auto-Tuning the Dryer Shutting Down the DryerPhotocopy this page for your maintenance records MaintenanceMaintenance Schedule Preventative Maintenance Cleaning or Replacing the Process Air FiltersCleaning or Replacing the Regeneration Filter Calibrating the Dirty Filter AlarmChecking the Dewpoint Control System Replacing the Desiccant Corrective MaintenanceSymptoms of Worn Out Desiccant Desiccant Tower Assembly Replacing the Process Heater Electric DryersProcess Heater Box Assembly Replacing the Regeneration Heater Electric DryersRegeneration Heater Box Assembly Introduction TroubleshootingBasic Troubleshooting Large Dehumidifying Dryers Troubleshooting Alarm Alarm Description Alarm Effect Code AlarmsAlarm Descriptions Using a Platinum Resistance Thermometer Determining Temperature Controller Errors or Sensor ErrorsUsing a Thermocouple Warranty AppendixAnnex B Information Technical SpecificationsAftercooler Design Specifications Drawings and Diagrams Optional dryer dust collector Spare Parts List Level 3 Mechanical Components Dryer Identification Serial Number Tag Located on back of DryerParts and Service Department Parts Department Service DepartmentTechnical Assistance Sales Department