Sterling SDA 1000-5100 specifications Reporting a Safety Defect

Page 11

When you need to perform maintenance or repair work on a dehumidifying dryer above floor level, use a solid platform or a hydraulic elevator. If there is a permanently installed catwalk on your dryer, use it. The work platform should have secure footing and a place for tools and parts. DO NOT climb on the dehumidifying dryer, machines, or work from ladders.

If you need to repair a large component, use appropriate handling equipment. Before you use handling equipment (portable “A” frames, electric boom trucks, fork trucks, overhead cranes) be sure the load does not exceed the capacity of the handling equipment or cause it to become unstable.

Carefully test the condition of lifting cables, chains, ropes, slings, and hooks before using them to lift a load.

Be sure that all non-current carrying parts are correctly connected to earth ground with an electrical conductor that complies with current codes. Install in accordance with national and local codes.

When you have completed the repair or maintenance procedure, check your work and remove your tools, rigging, and handling equipment.

Do not restore power to the dehumidifying dryer until all persons are clear of the area. DO NOT start and run the dryer until you are sure all parts are functioning correctly.

BEFORE you turn the dehumidifying dryer over to the operator for production, verify all enclosure panels, guards and safety devices are in place and functioning properly.

Reporting a Safety Defect

If you believe that your equipment has a defect that could cause injury, you should immediately discontinue its use and inform the manufacturer.

The principle factors that can result in injury are failure to follow proper operating procedures (i.e. lockout/tagout), or failure to maintain a clean and safe working environment.

Large Dehumidifying Dryers

Safety

11

Image 11
Contents SDA Large Dehumidifying Dryers With AP0 Controls If the Shipment is Not Complete Shipping InfoUnpacking and Inspection Event of Shipping DamageCredit Returns Warranty ReturnsReturns Table of Contents Operation Dryer Identification Serial Number Tag Technical Assistance Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves Dryer Safety Tags DescriptionOperator Responsibility ResponsibilityGeneral Responsibility Maintenance Responsibility Reporting a Safety Defect General Description Functional DescriptionModels Covered in This Manual Regeneration Cycle Process/Regeneration CycleSequence of Operation Controller Screen Descriptions Controller DescriptionElectrical Features Standard FeaturesMechanical Features Process Aftercooler OptionsClosed-Loop Regeneration Material Overdrying Protection Recommended Temperature SettingsProcess Air Dust Collector Electrical Options Mechanical OptionsFail Safe Operation Safety Devices and InterlocksSafety Circuit Standards Safety Device Lock-OutsPage Making Electrical Connections Mechanical InstallationUncrating the Equipment Rigging and Placing UnitChecking Blower Rotation Checking for Proper Blower RotationDryer/Drying Hopper Process Air Connections Making Dryer/Drying Hopper Process Air ConnectionsAftercooler Components & Flow Rates Connecting Aftercooler/Precooler Cooling Water OptionalDrying Hopper Air Trap Using the Drying Hopper Air TrapControls SwitchesIndicator Lights Process Air Temperature ControllerLights in the Operation Indicator Section when Lit when Control Output 1 is on. The Out1Lit when Control Output 2 is on. Not used Indicator Name DescriptionE5CN Operating Parameters Setting the Process Air TemperatureTuned prior to dryer startup Adjustment Level Indicator Name DescriptionON, OFF Entering Operating Parameters to Select ModesOptional Setting the High Dew Point AlarmProcess Air Dew Point Display Watlow Operating Parameters Redundant Safety Controller DisplaySetting the Redundant Safety Controller Manf. setting Pre-Startup Checks Auto-Tuning the DryerOperation Initial Start-upDryer Operation Procedures Page Material Miser OFF Press + to Enable Alarm Display Messages Shutting Down the Dryer Auto-Tuning the DryerPhotocopy this page for your maintenance records MaintenanceMaintenance Schedule Cleaning or Replacing the Process Air Filters Preventative MaintenanceCalibrating the Dirty Filter Alarm Cleaning or Replacing the Regeneration FilterChecking the Dewpoint Control System Replacing the Desiccant Corrective MaintenanceSymptoms of Worn Out Desiccant Replacing the Process Heater Electric Dryers Desiccant Tower AssemblyReplacing the Regeneration Heater Electric Dryers Process Heater Box AssemblyRegeneration Heater Box Assembly Introduction TroubleshootingBasic Troubleshooting Large Dehumidifying Dryers Troubleshooting Alarm Alarm Description Alarm Effect Code AlarmsAlarm Descriptions Using a Platinum Resistance Thermometer Determining Temperature Controller Errors or Sensor ErrorsUsing a Thermocouple Appendix WarrantyAnnex B Information Technical SpecificationsAftercooler Design Specifications Drawings and Diagrams Optional dryer dust collector Spare Parts List Level 3 Mechanical Components Located on back of Dryer Dryer Identification Serial Number TagParts and Service Department Sales Department Service DepartmentTechnical Assistance Parts Department