Available E5CN Modes
Operation Level
| Indicator | Name | Description |
|
|
|
|
|
| Run/Stop Mode | When “RUN” is selected, the control is running. |
|
| When “STOP” is selected, the control is stopped. | |
|
|
| When the control is stopped, the STOP display |
|
|
| lights. The default is set to “RUN.” |
|
|
|
|
|
| Alarm Value 1 | This setting is used to indicate how many degrees |
|
| Mode | the process temperature will be allowed to exceed |
|
|
| the set point temperature. An alarm output will de- |
|
|
| energize the heaters. |
|
|
|
|
Adjustment Level |
|
| |
|
|
|
|
| Indicator | Name | Description |
|
|
|
|
|
| See Page 41 of Chapter 5 for instructions on how | |
|
| (At) | to |
|
|
| Note: Although the controller is calibrated at |
|
|
| the factory, the manufacturer |
|
|
| recommends that the unit be Auto- |
|
|
| Tuned prior to dryer startup. |
|
|
|
|
|
| Temperature Input | This setting is used to offset an error between the |
|
| Shift Mode (TnS) | set point and the actual temperature. The entire |
|
|
| input range is shifted by a set figure |
|
|
| preprogrammed by the operator. |
|
|
|
|
|
| Proportional Band | This setting controls the amount in which the |
|
| Mode (P) | manipulated variable (MV) is proportionate to the |
|
|
| deviated value or controller error. |
|
|
|
|
|
| Integral Time | Setting this feature, gives the control an action that |
|
| Mode (I) | is proportionate to the time integral of the control |
|
|
| error. By using this setting, proportional action is |
|
|
| used in combination with integral action to offset |
|
|
| the control error and the set point will begin to |
|
|
| match the control temperature (PV or process |
|
|
| value). |
|
|
|
|
|
| Derivative Time | Setting the derivative control provides the |
|
| Mode (d) | controller with the ability to correct for a future |
|
|
| error in the previously set process output. |
|
|
|
|
Large Dehumidifying Dryers | Controls | 30 |