on the relay screen. Press ALARM RESET to deactivate the alarm until the next dew point fault occurs.
15.Use the right arrow key to display the REGEN SET screen (Screen 1). Use the up & down arrow keys to select the parameter to change. Use the + & - keys to change the parameter value. Press the OK key to accept and store the changed values. Press ESC to cancel changes.
REGEN
SET
HEAT 45
COOL 20
Screen 1.
16.Use the right arrow key to display the Material Miser screen. Use the + key to enable/ disable this feature. See Screens 2 & 3.
MATERIAL
MISER OFF
PRESS + TO
ENABLE
Screen 2.
MTL MISER ON
+TO DISABLE MM IS :
NOT ACTIVE
Screen 3.
17.Use the right arrow key to display the Closed Loop Regen screen. Use the + key to enable / disable this feature. See Screens 4 & 5.
CLOSED LOOP
REGEN OFF
PRESS + TO
ENABLE
Screen 4.
CL REGEN ON
+TO DISABLE CL IS :
NOT ACTIVE
Screen 5.
Large Dehumidifying Dryers | Operation | 38 |