Entering Operating Parameters to Select Modes
To enter the display:
1.Press both the Up and Down keys for three seconds from the home page. The word SEE will appear in the upper display and PAGE will appear in the lower display.
2.Press the Advance Key to move through the parameter prompts.
3.Press the Up or Down keys to change the parameter value.
4.Press the RESET Key at any time to return to the Home Page display.
Figure 15: Setting List for Redundant Safety Controller (WATLOW), Part No. A0555757
Mode | Parameter | Setting range | Default | Manf. setting | |
SEn | Sensor Type | 0 | - | ||
Lin | Thermocouple Linearization | 0 | H (1) | ||
Temperature Units | Fahrenheit / Celsius | F | - | ||
S.dEC | Temp. Decimal Places | 0 – 0.0 | 0 | - | |
IS.En | INFOSENSE™ | Yes / No | No | - | |
Sc.Lo | Process Scale Low | 4.00 to 20.00 mA | 4.00 mA | 0 | |
|
| 1.00 to 10.00V | 1.00V |
| |
Sc.hi | Process Scale High | 4.00 to 20.00 mA | 20.00 mA | 400 | |
|
| 1.00 to 10.00V | 5.00 V |
| |
CAL | Calibration Offset | 0 | - | ||
Ftr.E | Input Filter | Off, DiSP, Cont, both | OFF | - | |
Ot 1 | Output 1 Function | Limit (2) | (2) | - | |
LSd1 | Output 1 Limit Sides | Both, High, Low | Both | High | |
hyS1 | Limit 1 Hysteresis | 0.0 to 999.0 | 1.0 | - | |
Ot2 | Output 2 Function | Off / Process Alarm / Limit (2) | OFF | - | |
LSd2 | Output 2 Sides | Both / high / low | Both | - | |
|
| None, Process Value, Limit 1 Low Set, |
|
| |
|
| Limit 1 High Set, Limit 2 Low Set, Limit |
|
| |
UdSP | Upper Display Look | 2 High Set, Alarm 2 Low Set, Alarm 2 | Process | - | |
|
| High Set, Limit 3 Low Set, Limit 3 High |
|
| |
|
| Set, Alarm 3 Low Set, Alarm 3 High Set |
|
| |
|
| None, Process Value, Limit 1 Low Set, |
|
| |
|
| Limit 1 High Set, Limit 2 Low Set, Limit | Limit 1 |
| |
LdSP | Lower Display Look | 2 High Set, Alarm 2 Low Set, Alarm 2 | - | ||
High Set | |||||
|
| High Set, Limit 3 Low Set, Limit 3 High |
| ||
|
|
|
| ||
|
| Set, Alarm 3 Low Set, Alarm 3 High Set |
|
| |
|
| (0) no lockout, (1) Programming and |
|
| |
|
| Setup Page Locked, (2) Limit Set |
|
| |
LOC | Lockout | Points are the only Operation Page | 0 | 2 | |
|
| parameters accessible, (3) Full |
|
| |
|
| Lockout. |
|
|
Large Dehumidifying Dryers | Controls | 34 |