Roberts Gorden DAT115, DAT75, DAT90 Specifications 4.1 DAT all models, Front View Left Version

Page 11

SECTION 4: SPECIFICATIONS

SECTION 4: SPECIFICATIONS 4.1 DAT (all models)

Side View

 

 

3010

 

 

 

2070

532

 

1127

 

 

 

Air Intake 130 mm dia

 

 

896

225

Air Inlet Spigot

 

Flue 130 mm dia

734

 

 

(35 mm flange)

671

 

 

20 mm Conduit Entry

Gas

 

 

 

 

for Electrical Connections

 

 

Connection

 

 

 

 

 

 

 

 

 

Coil Protection,

 

 

 

 

Frost Thermostat

1494

 

 

 

& Pressure Switch

 

 

 

 

 

1417

Heater Section

Alternate

Fan Compartment

1239

Internal

 

 

Flue &

 

 

 

 

Spigot

 

 

Air Intake

 

 

 

 

Height

 

 

Position

 

 

 

 

 

 

Lockout

 

 

Electrical

Cooling Coil Condense Drain Filter Compartment

Air Outlet

Reset Red

Green

Amber

Connections

 

 

Spigot

Lockout

Burner Dirty Filter

(behind door)

 

 

(35 mm flange) Warning

On

Warning

 

 

 

Front View

1032

 

Standard Flue &

 

Front View (Left Version)

 

 

 

Air Intake

 

 

Air Intake Position

 

 

 

 

 

 

 

315

 

 

 

 

538

 

 

 

 

 

225

 

 

Alternate

 

 

 

 

Flue

 

 

 

 

Air

 

 

 

 

Position

 

 

 

 

 

Extension

Flue

51

890

399

Cover for

 

 

 

1340

Refrigerant

 

 

 

Pipe-work

 

 

 

1590

 

 

 

 

 

Rear View

1250 Internal Spigot Width

Rear View (Left Version)

 

 

 

1239

Internal

Spigot Height

5

Image 11
Contents DualAir Page 2005 Page Table of Figures Page Product Approval National Standards and Applicable Codes Clearances to CombustiblesCorrosive Chemicals Flue Minimum Required Installation ClearancesCritical Considerations 3.1 Basic Information Electrical SupplyInstallation Clearances and Clearances to Combustibles Front View Left Version Specifications 4.1 DAT all modelsModel 100 115 Fan Data General Technical Data Table all modelsModel 100 115 2 DAT100 and 115 4 kW motor Shelf Mounting and Suspension Heater Installation 5.1 GeneralHandling Flue Conversion Flue Installation 6.1 Flue InstallationType B22 Appliance Air Intake Terminal CoverControl Section & Upper Panel Vertical and Horizontal Flue Termination Type B22 Appliance Building Ventilation Room Sealed InstallationOpen Flued Installation Heaters Installed Within the Heated SpaceDuct resistance and design. Tel +44 0 Optional Heater Configurations 8.1 Distribution Duct14, .1 and to ensure that there is Department for recommendations regardingConnections Gas Connection with Stainless Steel Flex ConnectorSee Page 17, .3 through Page 18, Section Remote ControlRemote Frost Thermostat Number See Page 20, Section DAT Wiring Diagram ModelsSite wiring connections shown DAT Site Connections at Main Circuit Board Electrical Checks Gas Fired HeaterCooling Coils/Condensers LouversAutomatic Burner Control Box Sequence Set Minimum Pressure Combustion Testing all modelsCommissioning the Gas Valves Commissioning the Gas ValveInstruction to the User Pressure SwitchTurning Off the DualAir Unit Complete the CommissioningSee Page 7, .3 and Page 8, Figure See Page 26, SectionSee Page 25, Section Heater OperationCooling Section Operation Burner Lockout Reset ButtonSimple Fault Finding all models Simple Fault Finding burner faultsServicing 13.1 Servicing Instructions Burner Maintenance13.3 Fan/Motor Assembly Maintenance Heat Exchanger MaintenanceGas Control Valve Maintenance all models Gas Valves Conversion Between Gases 14.1 GeneralBurner Conversion Conduct Commissioning procedure as shown on Page 21, Section Result in death or electrical shock Troubleshooting For Automatic Ignition Burner SystemsStart Troubleshooting for Flame Supervision SystemTroubleshooting for Main Fan Troubleshooting for Solenoid ValvesConduct Commissioning procedure as on Page 21, Section Troubleshooting for Fan ContactorGas Valve Gas Valve Replacement all modelsBurner Components See Page 5, SectionBurner Injectors Burner CompartmentIgnition Electrode and Flame Probe Remove screws securing outlet flange to the flue adapter See Page 21, Section Heater Pressure SwitchFilter Pressure Switch Pressure SwitchesCoil Pressure Switch Fan Motor Removal Ignition Control16.7.1 S4563C Models 75 to Fan Removal and Replacement Combination Fan/Limit Thermostat Page Page Some objects can catch fire or explode when placed
Related manuals