AUTOMATIC OPERATION (Auto Changeover)

When you set the air conditioner in mode or switch over from AUTO operation because of some settings change, it will automatically select either cooling, heating, or fan only operation depending on the indoor temperature.

Start

1

2

button

Push this button to start the air conditioner.

Mode select button (MODE)

Select Auto.

3 Temperature button

Set the desired temperature.

In case of cooling, start the operation after approx. 1 minute.

In case of heating, the operation mode is selected in accordance with the room temperature and operation starts after approximately 3 to 5 minutes.

When you select the Auto mode, it is unnecessary to set the fan speed. The FAN speed display will show AUTO and the fan speed will be automatically controlled.

After the heating operation has stopped, FAN operation may continue for approx. 30 seconds.

When the room temperature reaches the set temperature and the outdoor unit stops, the supper low wind is discharged and the air volume decreases excessively. During defrost operation, the fan stops so that cool air is not discharged and “HEAT READY” is displayed.

If the Auto mode is uncomfortable, you can select the desired conditions manually.

NOTE

When restarting the operation after stop

When restarting the operation immediately after stop, the air conditioner does not operate for approx. 3 minutes to protect the machine.

Stop

Push button.

Push this button again to stop the air conditioner.

20

Image 23
Contents Split Type Adoption of NEW Refrigerant AccessoriesWay Air Discharge Cassette Type Installation ManualConnect the connecting cable correctly Precautions for SafetyNew Refrigerant Air Conditioner Installation To Disconnect the Appliance from Main Power SupplyInappropriate grounding may cause electric shock Before installation Accessory and RefrigerantSelection of Installation Accessory and Installation PartsObstacle at front side Upper side is free Installation PlaceNecessary Space for Installation Obstacle at rear side Upper side is freeObstacles at both front and rear sides Installation of Outdoor UnitStandard installation Serial installation at front and rear sidesPiping connection Knockout procedureRefrigerant Piping Connection For ReferencePipe Forming/End Positioning Refrigerant PipingRequirement Tightening of Connecting PartVacuum pump EvacuatingAir Purge How to close the valve How to open the valveElectrical Work How to wireStripping length power cord and connecting cable Single phase 50 HzSelf-Diagnosis by LED Indication Final Installation ChecksCheck and Test Operation New tools for R410A Applicable to R22 model Changes Changes in the product and componentsNew tools for R410A Precautions for Safety Accessories Sold SeparatelyRAV-SM1100AT-E RAV-SM1400AT-E Outdoor unit Parts NameIndoor unit Display section Parts Name of Remote ControllerOperation section Stop Turn on the main power switch and/or the leakage breakerCorrect Usage PreparationStart Mode select button ModeTemperature button When restarting the operation after stopHeat operation How to set up the wind directionHow to start swinging How to stop swingingCancel of timer operation Timer OperationTimer operation Get uniform circulation of room air Never open doors and windows more often than necessaryWindow curtains Checks before operation MaintenanceCleaning of remote controller If you do not plan to use the unit for more than 1 monthAIR Conditioner Operations and Performance Be careful with noise or vibrations RE-INSTALLATIONDo not install the air conditioner in the following places Troubles and CausesInoperative Part name Separate sold partsPart name ’ty Shape Usage Part name ’ty ShapePrecautions for Safety Inappropriate grounding may cause electric shock Model RAV Selection of Installation PlaceInstallation space Avoid installing in the following placesCeiling height Selection of installation place Discharge directionAdvice Height list of ceiling possible to be installedSM1400UT-E External viewModel RAV SM1100UT-EInstallation of ceiling opening and hanging bolt Installation of hanging boltInstallation of ceiling panel Sold separately Adhesive inhibited Drain Piping WorkPiping/Heat insulating material Flexible hosePerform heat insulating Connection procedureCheck the draining Drain upTightening torque of flare pipe connections Permissible Piping Length and HeatFlaring dia meter size a Unit mm Tightening connectionThermal insulation process Use a vacuum pumpOpen the valve fully Gas leak checkValve at gas side Packed valve handling precautionsRemote controller wiring Be sure to connect earth wire. Grounding workCabling on the ceiling panel Cable connectionCabling Remote Controller CablingCabling diagram Wiring diagramTest RUN How to execute a test runCase of wired remote controller ProcedureConfirmation and check TroubleshootingConfirmation of error history Maintenance Contents Accessories85464189556000 TCB-AX21U W-EName and Operation Precautions for SafetyRemote Controller Signal Receiving Part HOW to SET the FAN SpeedOperation Section Display SectionHOW to Operate the Timer HOW to Operate the UnitHOW to Insert the Batteries HOW to Adjust AIR DirectionSlide Switch Address HOW to Handle the Remote ControllerHOW to USE the Remote Controller Correctly Before asking a repair work, check the following items HOW to Perform Emergency OperationBefore Asking Repair Work StartRBC-EXW21E FeaturesTurn on the power supply of the air conditioner How to check the program operation timeName and Operation of Each Part HOW to USE the Timer Correctly Next set up the operation time to the program 2 When push SET Button,Set error When ON/OFF time is set as follows, Error is displayedClear of a part of the program Clearance of Holiday setupPush DAY button and put the operation To be checkedResuming of operation Matters to be memorized Power failureOperation of program weekly timer and air conditioner RBC-AS21E Start/Stop button Check button Used in servicing Temperature Setup buttonSelected mode displays Heat pump type Selected mode displays Cooling only typePush button Push button to select fan speed HOW to Operate AIR ConditionerPower supply Push either or set to Auto Recommended temperatureInstallation Manual For wireless remote controller Installation of adjust corner capInstallation of suction grille Check after installationRequirement to install Remote controller Accessory partsHow to install remote controller Requirement for installation Multiple remote controllersInstallation place Accessory partsRequirement for installation Multiple remote controllers Remote controller test run setupProgram weekly timer test run setup Accessory parts Part Name ’tyHow to install the program weekly timer Requirement to install Program weekly timerHow to install the remote sensor Accessory partsRequirement to install the remote sensor Drain-up Kit For Concealed Duct Type Indoor Unit To Personnel Charged in Installation Work and Service Combination List of Adapter Parts For Installation ProfessionalsUse for Indoor Unit Only ComponentsCase of Concealed Duct RAV-SM **0 BT-E Case of 4-way Ceiling Cassette RAV-SM **0 UT-EProcedure Address No. setup table SW01To Customers Contents Main

RAV-SM1400UT-E, RAV-SM1100UT-E specifications

Toshiba has consistently been recognized for its commitment to innovation and quality in the HVAC market, and the RAV-SM1100UT-E and RAV-SM1400UT-E models exemplify this dedication. These inverter air conditioners are designed to provide efficient cooling and heating solutions for diverse applications, ensuring comfort in both residential and commercial spaces.

One of the standout features of the RAV-SM1100UT-E and RAV-SM1400UT-E is their advanced inverter technology. This technology allows the units to adjust their cooling and heating capacities based on the real-time conditions, leading to significant energy savings compared to traditional fixed-speed systems. The inverter allows for smooth operation at varying speeds, reducing energy consumption while maintaining a consistent indoor climate.

Both models offer exceptional efficiency ratings. With a high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER), these units are designed to operate sustainably while delivering powerful performance. The RAV-SM1100UT-E offers a cooling capacity of 11 kW, while the RAV-SM1400UT-E boasts a more robust 14 kW, making them suitable for a range of spaces from smaller offices to larger commercial properties.

Another significant characteristic is their quiet operation. Toshiba has engineered these units to minimize noise levels, ensuring a tranquil environment. This is particularly beneficial in settings like hotels, restaurants, and workplaces where noise can be disruptive.

The RAV-SM series is also equipped with intelligent control technology. This feature allows users to manage the system from anywhere using a smartphone app, providing convenience and flexibility. Integration with smart home systems further enhances usability, making it easy to program schedules and adjust settings remotely.

Additionally, both models employ a variety of robust filtration systems, ensuring that the circulated air is clean and healthy. With filters that capture dust, allergens, and other particles, these units contribute to improved indoor air quality.

Durability is another hallmark of Toshiba's design philosophy. These air conditioners are built with high-quality materials, ensuring long-lasting performance and reliability even in demanding environments. The RAV-SM models are also designed to work efficiently in low outdoor temperatures, extending their usefulness throughout the year.

In summary, the Toshiba RAV-SM1100UT-E and RAV-SM1400UT-E air conditioners represent a fusion of innovation, efficiency, and user-centric design. With their advanced inverter technology, energy efficiency, quiet operation, intelligent controls, and durable construction, they stand as ideal solutions for those seeking effective climate management in their spaces.