Toshiba RAV-SM1400UT-E, RAV-SM1100UT-E HOW to Operate the Unit, HOW to Operate the Timer

Page 55

HOW TO OPERATE THE UNIT

Cool/Heat AUTO, Heat, Dry, Cool, Fan

Power supply

HOW TO OPERATE THE TIMER

After setting of the timer, set the remote controller at a position where the signal can reach the sensors (indoor unit body) .

(The signal of the timer operation is sent from the remote controller.)

Set up the timer during display of the operation mode.

Turn on the power of the wireless remote controller 12 hours before starting the operation.

After the power supply has been turned on, the operation of the remote controller is not accepted for approx. 1 minute. It is not a failure.

(The sensor receives the signal once, but the received contents are cleared.)

Use in the following cases

During display

To stop the air conditioner after the previously set time has passed

<Use example>

How to use OFF timer

(Ex.) To stop the unit 30 minutes after

2

3

1

4

1

Push Start/Stop button.

2

Push (Operation Select button)

 

operation to select one of , ,

, , and .

3 Push (Fan Mode Select button) to select one of fan speed modes.

When selecting , the fan speed is automatically changed.

(During FAN mode, the air speed is not automatically changed.)

To stop the air conditioner every time after the previously set time has passed

To operate the air conditioner after the previously set time has passed

Timer time

Every pushing , the setup time increases by 0.5 hour (30 minutes).

1When pushing the timer SET once,

and the time flash on the remote controller.

2Push TIME or to set the time to 0.5.

3Push SET and the go on timer.

How to use the repeat timer

(Ex.) To stop the air conditioner every time after 2.5 hours has passed

1 When pushing the timer SET twice,

52

4 Push either or to select the desired temperature.

During FAN mode, the temperature cannot be set up.

5 Stop

Push Start/Stop button.

When using the remote controller to stop the unit, the outdoor unit fan may keep operating for a while even if the compressor of the outdoor unit has stopped.

• In heating operation, if the room is not comf or tably heated with FAN , select FAN

or .

Although they are displayed, the function may not be provided according to the used indoor unit. (Fan speed is constant.)

When the unit cannot be stopped by the normal operation

Turn off the power switch or leakage breaker, and then contact the shop which you purchased the unit.

Automatic cool/heat

When all indoor units in the identical refrigerant system are controlled as a group, the cooling/ heating operation is automatically performed with the difference between the setup temperature and the room temperature.

Dry operation

There is no dry function according to the used indoor unit even if DRY is displayed on the display section of the remote controller. (Same to Cooling operation)

When the room temperature approaches the setup temperature, running/stop operations are automatically repeated.

In order not to return humidity to the room as possible, the mode of indoor fan enters LOW mode when the operation has stopped.

The fan speed cannot be adjusted according to the used indoor unit or status of the room temperature.

The DRY mode cannot be used according to the used indoor unit when the outdoor tempera- ture is 15˚C or lower.

The maximum time to be set is 72.0 hours.

Every pushing , the setup time decreases by

0.5 hour (30 minutes).

The minimum time to be set is 0.5 hours.

Timer display

Every pushing SET , the display changes as follows;

ADR

No display

 

,

and the time flash on the

 

remote controller.

 

2

Push TIME

or

to set the time

 

to 2.5.

 

 

 

3

Push

SET and the ,

go on

 

timer.

 

 

 

 

The

works, and the operation stops

 

after 2.5 hours. When pushing

 

(Start/Stop) button again to operate the

 

unit, the operation stops after 2.5 hours.

How to use ON timer

(Ex.) To operate the unit 8 hours after

1When pushing the timer SET three

times, and the timer flash on the remote controller.

2Push TIME or to set the time to 8.0.

3Push SET

The operation mode display disappears,

and then time and the go on.

To stop the timer operation

To stop the timer operation

Push C L button. Then the timer display disappears.

Image 55
Contents Split Type Adoption of NEW Refrigerant AccessoriesWay Air Discharge Cassette Type Installation ManualConnect the connecting cable correctly Precautions for SafetyNew Refrigerant Air Conditioner Installation To Disconnect the Appliance from Main Power SupplyInappropriate grounding may cause electric shock Before installation Accessory and RefrigerantSelection of Installation Accessory and Installation PartsObstacle at front side Upper side is free Installation PlaceNecessary Space for Installation Obstacle at rear side Upper side is freeObstacles at both front and rear sides Installation of Outdoor UnitStandard installation Serial installation at front and rear sidesPiping connection Knockout procedureRefrigerant Piping Connection For ReferencePipe Forming/End Positioning Refrigerant PipingRequirement Tightening of Connecting PartAir Purge EvacuatingVacuum pump How to close the valve How to open the valveElectrical Work How to wireStripping length power cord and connecting cable Single phase 50 HzCheck and Test Operation Final Installation ChecksSelf-Diagnosis by LED Indication New tools for R410A Changes in the product and componentsNew tools for R410A Applicable to R22 model Changes Precautions for Safety Accessories Sold SeparatelyRAV-SM1100AT-E RAV-SM1400AT-E Indoor unit Parts NameOutdoor unit Display section Parts Name of Remote ControllerOperation section Stop Turn on the main power switch and/or the leakage breakerCorrect Usage PreparationStart Mode select button ModeTemperature button When restarting the operation after stopHeat operation How to set up the wind directionHow to start swinging How to stop swingingTimer operation Timer OperationCancel of timer operation Window curtains Never open doors and windows more often than necessaryGet uniform circulation of room air Checks before operation MaintenanceCleaning of remote controller If you do not plan to use the unit for more than 1 monthAIR Conditioner Operations and Performance Be careful with noise or vibrations RE-INSTALLATIONDo not install the air conditioner in the following places Troubles and CausesInoperative Part name Separate sold partsPart name ’ty Shape Usage Part name ’ty ShapePrecautions for Safety Inappropriate grounding may cause electric shock Model RAV Selection of Installation PlaceInstallation space Avoid installing in the following placesCeiling height Selection of installation place Discharge directionAdvice Height list of ceiling possible to be installedSM1400UT-E External viewModel RAV SM1100UT-EInstallation of ceiling opening and hanging bolt Installation of hanging boltInstallation of ceiling panel Sold separately Adhesive inhibited Drain Piping WorkPiping/Heat insulating material Flexible hosePerform heat insulating Connection procedureCheck the draining Drain upTightening torque of flare pipe connections Permissible Piping Length and HeatFlaring dia meter size a Unit mm Tightening connectionThermal insulation process Use a vacuum pumpOpen the valve fully Gas leak checkValve at gas side Packed valve handling precautionsRemote controller wiring Be sure to connect earth wire. Grounding workCabling on the ceiling panel Cable connectionCabling Remote Controller CablingCabling diagram Wiring diagramTest RUN How to execute a test runCase of wired remote controller ProcedureConfirmation of error history TroubleshootingConfirmation and check Maintenance Contents Accessories85464189556000 TCB-AX21U W-ERemote Controller Precautions for SafetyName and Operation Signal Receiving Part HOW to SET the FAN SpeedOperation Section Display SectionHOW to Operate the Timer HOW to Operate the UnitSlide Switch HOW to Adjust AIR DirectionHOW to Insert the Batteries HOW to USE the Remote Controller Correctly HOW to Handle the Remote ControllerAddress Before asking a repair work, check the following items HOW to Perform Emergency OperationBefore Asking Repair Work StartRBC-EXW21E FeaturesTurn on the power supply of the air conditioner How to check the program operation timeName and Operation of Each Part HOW to USE the Timer Correctly Next set up the operation time to the program 2 When push SET Button,Set error When ON/OFF time is set as follows, Error is displayedClear of a part of the program Clearance of Holiday setupPush DAY button and put the operation To be checkedOperation of program weekly timer and air conditioner Matters to be memorized Power failureResuming of operation RBC-AS21E Start/Stop button Check button Used in servicing Temperature Setup buttonSelected mode displays Heat pump type Selected mode displays Cooling only typePush button Push button to select fan speed HOW to Operate AIR ConditionerPower supply Push either or set to Auto Recommended temperatureInstallation Manual For wireless remote controller Installation of adjust corner capInstallation of suction grille Check after installationRequirement to install Remote controller Accessory partsHow to install remote controller Requirement for installation Multiple remote controllersInstallation place Accessory partsRequirement for installation Multiple remote controllers Remote controller test run setupProgram weekly timer test run setup Accessory parts Part Name ’tyHow to install the program weekly timer Requirement to install Program weekly timerRequirement to install the remote sensor Accessory partsHow to install the remote sensor Drain-up Kit For Concealed Duct Type Indoor Unit To Personnel Charged in Installation Work and Service Combination List of Adapter Parts For Installation ProfessionalsUse for Indoor Unit Only ComponentsCase of Concealed Duct RAV-SM **0 BT-E Case of 4-way Ceiling Cassette RAV-SM **0 UT-EProcedure Address No. setup table SW01To Customers Contents Main

RAV-SM1400UT-E, RAV-SM1100UT-E specifications

Toshiba has consistently been recognized for its commitment to innovation and quality in the HVAC market, and the RAV-SM1100UT-E and RAV-SM1400UT-E models exemplify this dedication. These inverter air conditioners are designed to provide efficient cooling and heating solutions for diverse applications, ensuring comfort in both residential and commercial spaces.

One of the standout features of the RAV-SM1100UT-E and RAV-SM1400UT-E is their advanced inverter technology. This technology allows the units to adjust their cooling and heating capacities based on the real-time conditions, leading to significant energy savings compared to traditional fixed-speed systems. The inverter allows for smooth operation at varying speeds, reducing energy consumption while maintaining a consistent indoor climate.

Both models offer exceptional efficiency ratings. With a high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER), these units are designed to operate sustainably while delivering powerful performance. The RAV-SM1100UT-E offers a cooling capacity of 11 kW, while the RAV-SM1400UT-E boasts a more robust 14 kW, making them suitable for a range of spaces from smaller offices to larger commercial properties.

Another significant characteristic is their quiet operation. Toshiba has engineered these units to minimize noise levels, ensuring a tranquil environment. This is particularly beneficial in settings like hotels, restaurants, and workplaces where noise can be disruptive.

The RAV-SM series is also equipped with intelligent control technology. This feature allows users to manage the system from anywhere using a smartphone app, providing convenience and flexibility. Integration with smart home systems further enhances usability, making it easy to program schedules and adjust settings remotely.

Additionally, both models employ a variety of robust filtration systems, ensuring that the circulated air is clean and healthy. With filters that capture dust, allergens, and other particles, these units contribute to improved indoor air quality.

Durability is another hallmark of Toshiba's design philosophy. These air conditioners are built with high-quality materials, ensuring long-lasting performance and reliability even in demanding environments. The RAV-SM models are also designed to work efficiently in low outdoor temperatures, extending their usefulness throughout the year.

In summary, the Toshiba RAV-SM1100UT-E and RAV-SM1400UT-E air conditioners represent a fusion of innovation, efficiency, and user-centric design. With their advanced inverter technology, energy efficiency, quiet operation, intelligent controls, and durable construction, they stand as ideal solutions for those seeking effective climate management in their spaces.