Toshiba RAV-SM1400UT-E, RAV-SM1100UT-E Separate sold parts, Part name ’ty Shape Usage

Page 31

Accessory parts and Parts to be procured locally

HAccessory parts

Part name

Q’ty

Shape

Usage

 

 

 

 

Installation

1

This

(Be sure to hand over to customers)

Manual

manual

 

 

Heat insulating

2

 

For heat insulation of pipe

pipe

 

connecting section

 

 

 

 

 

 

Installation

1

——

For confirmation of ceiling opening

pattern

and main unit position

 

 

 

 

 

 

Installation

2

 

For positioning of ceiling position

gauge

 

(united with installation pattern)

 

 

 

 

 

 

Pattern fixing

4

M5 x 16L

For attach the installation pattern

screw

 

 

 

Heat insulator

1

 

For heat insulation of drain

 

connecting section

 

 

 

 

 

 

 

<Separate sold parts>

Part name

Q’ty Shape

Usage

Standard wired

1

Model

remote controller

RBC-AMT21E

 

HParts to be procured locally

Part name

Q’ty Shape

Usage

Washer

8

For hanging-down unit

Hose band

1

For connecting drain pipe

Flexible hose

1

For adjusting core-out of drain

pipe

 

 

Heat insulator

1

For sealing of wire connecting port

Owner’s

1

(Be sure to hand over to customers)

Manual

 

 

Part name

Q’ty

Shape

Usage

Ceiling panel

1

 

Model

 

RBC-U21PG (W)-E

 

 

 

RAV-SM1100AT-E RAV-SM1400AT-E

Connecting pipe (Liquid side)

(6.35mm (diam.), Nominal (diam.) 1/4” thick 0.8mm) RAV-SM560UT-E, RAV-SM560AT-E

(9.52mm (diam.), Nominal (diam.) 3/8” thick 0.8mm) RAV-SM800UT-E, RAV-SM800AT-E RAV-SM1100UT-E, RAV-SM1100AT-E RAV-SM1400UT-E, RAV-SM1400AT-E

Connecting pipe (Gas side)

(12.7mm (diam.), Nominal (diam.) 1/2” thick 0.8mm) RAV-SM560UT-E, RAV-SM560AT-E

(15.9mm (diam.), Nominal (diam.) 5/8” thick 1.0mm) RAV-SM800UT-E, RAV-SM800AT-E RAV-SM1100UT-E, RAV-SM1100AT-E RAV-SM1400UT-E, RAV-SM1400AT-E

Power supply cord

2.5mm² (H07RN-F or 245IEC66) or 3.5mm² (AWG-12)

Connecting cable (indoor and outdoor cable) H07RN-F or 245IEC66 (1.5mm² or more)

Thermal insulation for refrigerant pipe

(10mm or more, thermal insulating foam polyethylene)

Thermal insulation for drain pipe (10mm or more, foam polyethylene)

Drain pipe (Outer 26mm (diam.))

Tapes

Grounding cable (2.0mm (diam.) or more)

28

Image 31
Contents Split Type Adoption of NEW Refrigerant AccessoriesWay Air Discharge Cassette Type Installation ManualConnect the connecting cable correctly Precautions for SafetyNew Refrigerant Air Conditioner Installation To Disconnect the Appliance from Main Power SupplyInappropriate grounding may cause electric shock Before installation Accessory and RefrigerantSelection of Installation Accessory and Installation PartsObstacle at front side Upper side is free Installation PlaceNecessary Space for Installation Obstacle at rear side Upper side is freeObstacles at both front and rear sides Installation of Outdoor UnitStandard installation Serial installation at front and rear sidesPiping connection Knockout procedureRefrigerant Piping Connection For ReferencePipe Forming/End Positioning Refrigerant PipingRequirement Tightening of Connecting PartAir Purge EvacuatingVacuum pump How to close the valve How to open the valveElectrical Work How to wireStripping length power cord and connecting cable Single phase 50 HzCheck and Test Operation Final Installation ChecksSelf-Diagnosis by LED Indication New tools for R410A Changes in the product and componentsNew tools for R410A Applicable to R22 model Changes Precautions for Safety Accessories Sold SeparatelyRAV-SM1100AT-E RAV-SM1400AT-E Indoor unit Parts NameOutdoor unit Display section Parts Name of Remote ControllerOperation section Stop Turn on the main power switch and/or the leakage breakerCorrect Usage PreparationStart Mode select button ModeTemperature button When restarting the operation after stopHeat operation How to set up the wind directionHow to start swinging How to stop swingingTimer operation Timer OperationCancel of timer operation Window curtains Never open doors and windows more often than necessaryGet uniform circulation of room air Checks before operation MaintenanceCleaning of remote controller If you do not plan to use the unit for more than 1 monthAIR Conditioner Operations and Performance Be careful with noise or vibrations RE-INSTALLATIONDo not install the air conditioner in the following places Troubles and CausesInoperative Part name Separate sold partsPart name ’ty Shape Usage Part name ’ty ShapePrecautions for Safety Inappropriate grounding may cause electric shock Model RAV Selection of Installation PlaceInstallation space Avoid installing in the following placesCeiling height Selection of installation place Discharge directionAdvice Height list of ceiling possible to be installedSM1400UT-E External viewModel RAV SM1100UT-EInstallation of ceiling opening and hanging bolt Installation of hanging boltInstallation of ceiling panel Sold separately Adhesive inhibited Drain Piping WorkPiping/Heat insulating material Flexible hosePerform heat insulating Connection procedureCheck the draining Drain upTightening torque of flare pipe connections Permissible Piping Length and HeatFlaring dia meter size a Unit mm Tightening connectionThermal insulation process Use a vacuum pumpOpen the valve fully Gas leak checkValve at gas side Packed valve handling precautionsRemote controller wiring Be sure to connect earth wire. Grounding workCabling on the ceiling panel Cable connectionCabling Remote Controller CablingCabling diagram Wiring diagramTest RUN How to execute a test runCase of wired remote controller ProcedureConfirmation of error history TroubleshootingConfirmation and check Maintenance Contents Accessories85464189556000 TCB-AX21U W-ERemote Controller Precautions for SafetyName and Operation Signal Receiving Part HOW to SET the FAN SpeedOperation Section Display SectionHOW to Operate the Timer HOW to Operate the UnitSlide Switch HOW to Adjust AIR DirectionHOW to Insert the Batteries HOW to USE the Remote Controller Correctly HOW to Handle the Remote ControllerAddress Before asking a repair work, check the following items HOW to Perform Emergency OperationBefore Asking Repair Work StartRBC-EXW21E FeaturesTurn on the power supply of the air conditioner How to check the program operation timeName and Operation of Each Part HOW to USE the Timer Correctly Next set up the operation time to the program 2 When push SET Button,Set error When ON/OFF time is set as follows, Error is displayedClear of a part of the program Clearance of Holiday setupPush DAY button and put the operation To be checkedOperation of program weekly timer and air conditioner Matters to be memorized Power failureResuming of operation RBC-AS21E Start/Stop button Check button Used in servicing Temperature Setup buttonSelected mode displays Heat pump type Selected mode displays Cooling only typePush button Push button to select fan speed HOW to Operate AIR ConditionerPower supply Push either or set to Auto Recommended temperatureInstallation Manual For wireless remote controller Installation of adjust corner capInstallation of suction grille Check after installationRequirement to install Remote controller Accessory partsHow to install remote controller Requirement for installation Multiple remote controllersInstallation place Accessory partsRequirement for installation Multiple remote controllers Remote controller test run setupProgram weekly timer test run setup Accessory parts Part Name ’tyHow to install the program weekly timer Requirement to install Program weekly timerRequirement to install the remote sensor Accessory partsHow to install the remote sensor Drain-up Kit For Concealed Duct Type Indoor Unit To Personnel Charged in Installation Work and Service Combination List of Adapter Parts For Installation ProfessionalsUse for Indoor Unit Only ComponentsCase of Concealed Duct RAV-SM **0 BT-E Case of 4-way Ceiling Cassette RAV-SM **0 UT-EProcedure Address No. setup table SW01To Customers Contents Main

RAV-SM1400UT-E, RAV-SM1100UT-E specifications

Toshiba has consistently been recognized for its commitment to innovation and quality in the HVAC market, and the RAV-SM1100UT-E and RAV-SM1400UT-E models exemplify this dedication. These inverter air conditioners are designed to provide efficient cooling and heating solutions for diverse applications, ensuring comfort in both residential and commercial spaces.

One of the standout features of the RAV-SM1100UT-E and RAV-SM1400UT-E is their advanced inverter technology. This technology allows the units to adjust their cooling and heating capacities based on the real-time conditions, leading to significant energy savings compared to traditional fixed-speed systems. The inverter allows for smooth operation at varying speeds, reducing energy consumption while maintaining a consistent indoor climate.

Both models offer exceptional efficiency ratings. With a high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER), these units are designed to operate sustainably while delivering powerful performance. The RAV-SM1100UT-E offers a cooling capacity of 11 kW, while the RAV-SM1400UT-E boasts a more robust 14 kW, making them suitable for a range of spaces from smaller offices to larger commercial properties.

Another significant characteristic is their quiet operation. Toshiba has engineered these units to minimize noise levels, ensuring a tranquil environment. This is particularly beneficial in settings like hotels, restaurants, and workplaces where noise can be disruptive.

The RAV-SM series is also equipped with intelligent control technology. This feature allows users to manage the system from anywhere using a smartphone app, providing convenience and flexibility. Integration with smart home systems further enhances usability, making it easy to program schedules and adjust settings remotely.

Additionally, both models employ a variety of robust filtration systems, ensuring that the circulated air is clean and healthy. With filters that capture dust, allergens, and other particles, these units contribute to improved indoor air quality.

Durability is another hallmark of Toshiba's design philosophy. These air conditioners are built with high-quality materials, ensuring long-lasting performance and reliability even in demanding environments. The RAV-SM models are also designed to work efficiently in low outdoor temperatures, extending their usefulness throughout the year.

In summary, the Toshiba RAV-SM1100UT-E and RAV-SM1400UT-E air conditioners represent a fusion of innovation, efficiency, and user-centric design. With their advanced inverter technology, energy efficiency, quiet operation, intelligent controls, and durable construction, they stand as ideal solutions for those seeking effective climate management in their spaces.