Toshiba RAV-SM1400UT-E Installation of adjust corner cap, Installation of suction grille

Page 69

(3) Installation of ceiling panel

The angle change of the flap is possible while the power supply is turned on. (Do not move forcibly the flap with hands. It may break the flap.)

1.For tentative hanging, insert the tentative hanging metal (stainless) inside of the ceiling panel into the square hole of the indoor unit. (Fig. 2)

Square hole of indoor unit

Push to remove

(5) Installation of adjust corner cap/suction grille

Install the adjust corner cap/suction grille in the reverse procedure of installation to the indoor unit.

• For this ceiling panel, as shown in the following figure, the

direction of the suction grille can be changed on customer’s

Pin

The ceiling panel has directional ability against the indoor unit. Direct the mark of refrigerant pipe at the ceiling panel corner toward the pipe side.

Holding the ceiling panel, remove it while pushing the tentative hanging metal toward the outside.

2.Match the mounting hole of the panel with the screw hole of the indoor unit.

3.Using the attached screws with washer, tighten 4 positions at corners of the suction port until the panel is fitted closely to the main unit. (Fig. 3)

4. Check the panel is fitted closely to the ceiling.

In this time, check there is no clearance between the indoor unit

and the ceiling panel, and between the ceiling panel and the

Ceiling panel

ceiling surface. (Fig. 4)

 

Tentative hanging metal

(Fig. 2)

Corner of drain pipe

Square hole of indoor unit

Draining mark

demand when multiple indoor units are installed.

A.Installation of adjust corner cap

1.Hook the strap of the adjust corner cap surely to the pin on the ceiling panel.

2.Install the adjust corner cap to the ceiling panel, and fix it with the mounting screws. (accessory part)

B.Installation of suction grille

• To install the suction grille, follow to the reverse procedure of the

removal. This ceiling panel can be installed from anyone of 4

directions by turning the suction grille. Change the direction on

the customer’s demand or according to the direction matching of

Install the adjust corner cap horizontally to the ceiling surface so that 3 hooks of the adjust corner cap are set in holes of the ceiling panel. And then fix it with the mounting screws (accessory part).

Hook hole of ceiling panel

 

Indoor unit

No clearance

 

 

 

 

 

Screw

Mark of

(Fig. 4)

Ceiling surface

Ceiling panel

(Fig. 3) with washer

refrigerant pipe

Tentative hanging metal

CAUTIONS

 

the suction grille when multiple units are installed.

When installing the suction grille, be sure not to pinch the

 

flap motor wiring connector.

Be sure to attach a strap to prevent falling of the suction grille to

 

the ceiling panel.

(Fig. 8)

Hook of fall-preventive strap

66

Tighten the screws securely because • When there is a clearance between the

a trouble is caused as shown in the

ceiling surface and the ceiling panel

following figure if the screws are

even if the screws have been tightened,

incompletely tightened.

readjust height of the indoor unit.

Air leak

 

The height of the indoor unit can be adjusted from corner hole on the ceiling panel as the ceiling panel is installed if the adjustment does not affect the levelness of the indoor unit, drain pipe, etc.

3. Others

Air leak

 

 

from ceiling

 

 

Generation

Dewing/water

Adjust so that there is

of dust

leak

no clearance.

(Fig. 5)

(Fig. 6)

After adjustment, be sure to tighten the mounting nut of the indoor unit securely.

Positions of suction grille hooks at shipment from the factory

 

 

* Although the suction grille can be installed from any

Drain pipe side

position of 4 corners, these positions are recommended.

of indoor unit

It is unnecessary to remove the suction grille in

 

 

(maintenance for the electric parts box of the indoor unit. )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Check after installation

 

Electric parts box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check again there is no clearance between the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of indoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant pipe side of indoor unit

Wireless remote controller kit (sold separately)

(Fig. 9)

 

(4) Cabling of ceiling panel

1.

Open cover of the electric parts box.

2.

Connect the flap motor wiring connector out

 

of the ceiling panel to the connector 5P

Wiring explanation diagram

(For explanation, direction of the indoor unit is changed.)

Electric parts box cover

indoor unit and the ceiling panel, and between the ceiling panel and the ceiling surface.

*A clearance causes water leak or dewing.

Check the cables are connected surely.

*Incomplete connection causes a trouble such as the flap does not work.

(CN33: white) on P.C. board of the indoor unit.

Screws

Flap motor wiring connector

Connect the connector surely because

 

the flap does not work if the connector

 

is not connected.

3. Mount cover of the electric parts box in the

reverse procedure of opening of the cover.

Check whether the wiring connector is

 

pinched between the electric parts box

 

and the cover or not.

Check whether the wiring connector is

 

pinched between the indoor unit and the

 

ceiling panel or not.

(3 positions)

CN33

Clamper

As shown in the figure, pass the clamping material through inside of the slit. After connection, store the connector section in the electric parts box.

(Fig. 7)

B. For wireless remote controller

Direction-free in 360˚

• For details of installation, refer to the Installation Manual attached to the wireless remote controller kit (sold separately).

After confirmation of the above items, hand a set of this manual, manuals for the indoor unit, manual for products sold separately, etc. to the customer. For cleaning of the filter, be sure to ask the maintenance professional.

EH99708701-(1) (EN)

Image 69
Contents Split Type Adoption of NEW Refrigerant AccessoriesWay Air Discharge Cassette Type Installation ManualNew Refrigerant Air Conditioner Installation Precautions for SafetyTo Disconnect the Appliance from Main Power Supply Connect the connecting cable correctlyInappropriate grounding may cause electric shock Selection of Installation Accessory and RefrigerantAccessory and Installation Parts Before installationNecessary Space for Installation Installation PlaceObstacle at rear side Upper side is free Obstacle at front side Upper side is freeStandard installation Installation of Outdoor UnitSerial installation at front and rear sides Obstacles at both front and rear sidesRefrigerant Piping Connection Knockout procedureFor Reference Piping connectionPipe Forming/End Positioning Refrigerant PipingRequirement Tightening of Connecting PartEvacuating Air PurgeVacuum pump How to close the valve How to open the valveStripping length power cord and connecting cable How to wireSingle phase 50 Hz Electrical WorkFinal Installation Checks Check and Test OperationSelf-Diagnosis by LED Indication Changes in the product and components New tools for R410ANew tools for R410A Applicable to R22 model Changes Precautions for Safety Accessories Sold SeparatelyRAV-SM1100AT-E RAV-SM1400AT-E Parts Name Indoor unitOutdoor unit Display section Parts Name of Remote ControllerOperation section Correct Usage Turn on the main power switch and/or the leakage breakerPreparation StopTemperature button Mode select button ModeWhen restarting the operation after stop StartHow to start swinging How to set up the wind directionHow to stop swinging Heat operationTimer Operation Timer operationCancel of timer operation Never open doors and windows more often than necessary Window curtainsGet uniform circulation of room air Cleaning of remote controller MaintenanceIf you do not plan to use the unit for more than 1 month Checks before operationAIR Conditioner Operations and Performance Do not install the air conditioner in the following places RE-INSTALLATIONTroubles and Causes Be careful with noise or vibrationsInoperative Part name ’ty Shape Usage Separate sold partsPart name ’ty Shape Part namePrecautions for Safety Inappropriate grounding may cause electric shock Installation space Selection of Installation PlaceAvoid installing in the following places Model RAVAdvice Selection of installation place Discharge directionHeight list of ceiling possible to be installed Ceiling heightModel RAV External viewSM1100UT-E SM1400UT-EInstallation of ceiling opening and hanging bolt Installation of hanging boltInstallation of ceiling panel Sold separately Piping/Heat insulating material Drain Piping WorkFlexible hose Adhesive inhibitedCheck the draining Connection procedureDrain up Perform heat insulatingFlaring dia meter size a Unit mm Permissible Piping Length and HeatTightening connection Tightening torque of flare pipe connectionsOpen the valve fully Use a vacuum pumpGas leak check Thermal insulation processValve at gas side Packed valve handling precautionsRemote controller wiring Be sure to connect earth wire. Grounding workCabling on the ceiling panel Cable connectionCabling diagram Remote Controller CablingWiring diagram CablingCase of wired remote controller How to execute a test runProcedure Test RUNTroubleshooting Confirmation of error historyConfirmation and check Maintenance Contents Accessories85464189556000 TCB-AX21U W-EPrecautions for Safety Remote ControllerName and Operation Signal Receiving Part HOW to SET the FAN SpeedOperation Section Display SectionHOW to Operate the Timer HOW to Operate the UnitHOW to Adjust AIR Direction Slide SwitchHOW to Insert the Batteries HOW to Handle the Remote Controller HOW to USE the Remote Controller CorrectlyAddress Before Asking Repair Work HOW to Perform Emergency OperationStart Before asking a repair work, check the following itemsTurn on the power supply of the air conditioner FeaturesHow to check the program operation time RBC-EXW21EName and Operation of Each Part HOW to USE the Timer Correctly Set error When push SET Button,When ON/OFF time is set as follows, Error is displayed Next set up the operation time to the program 2Push DAY button and put the operation Clearance of Holiday setupTo be checked Clear of a part of the programMatters to be memorized Power failure Operation of program weekly timer and air conditionerResuming of operation RBC-AS21E Selected mode displays Heat pump type Temperature Setup buttonSelected mode displays Cooling only type Start/Stop button Check button Used in servicingPower supply HOW to Operate AIR ConditionerPush either or set to Auto Recommended temperature Push button Push button to select fan speedInstallation Manual Installation of suction grille Installation of adjust corner capCheck after installation For wireless remote controllerHow to install remote controller Accessory partsRequirement for installation Multiple remote controllers Requirement to install Remote controllerRequirement for installation Multiple remote controllers Accessory partsRemote controller test run setup Installation placeHow to install the program weekly timer Accessory parts Part Name ’tyRequirement to install Program weekly timer Program weekly timer test run setupAccessory parts Requirement to install the remote sensorHow to install the remote sensor Drain-up Kit For Concealed Duct Type Indoor Unit To Personnel Charged in Installation Work and Service Use for Indoor Unit Only For Installation ProfessionalsComponents Combination List of Adapter PartsCase of Concealed Duct RAV-SM **0 BT-E Case of 4-way Ceiling Cassette RAV-SM **0 UT-EProcedure Address No. setup table SW01To Customers Contents Main

RAV-SM1400UT-E, RAV-SM1100UT-E specifications

Toshiba has consistently been recognized for its commitment to innovation and quality in the HVAC market, and the RAV-SM1100UT-E and RAV-SM1400UT-E models exemplify this dedication. These inverter air conditioners are designed to provide efficient cooling and heating solutions for diverse applications, ensuring comfort in both residential and commercial spaces.

One of the standout features of the RAV-SM1100UT-E and RAV-SM1400UT-E is their advanced inverter technology. This technology allows the units to adjust their cooling and heating capacities based on the real-time conditions, leading to significant energy savings compared to traditional fixed-speed systems. The inverter allows for smooth operation at varying speeds, reducing energy consumption while maintaining a consistent indoor climate.

Both models offer exceptional efficiency ratings. With a high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER), these units are designed to operate sustainably while delivering powerful performance. The RAV-SM1100UT-E offers a cooling capacity of 11 kW, while the RAV-SM1400UT-E boasts a more robust 14 kW, making them suitable for a range of spaces from smaller offices to larger commercial properties.

Another significant characteristic is their quiet operation. Toshiba has engineered these units to minimize noise levels, ensuring a tranquil environment. This is particularly beneficial in settings like hotels, restaurants, and workplaces where noise can be disruptive.

The RAV-SM series is also equipped with intelligent control technology. This feature allows users to manage the system from anywhere using a smartphone app, providing convenience and flexibility. Integration with smart home systems further enhances usability, making it easy to program schedules and adjust settings remotely.

Additionally, both models employ a variety of robust filtration systems, ensuring that the circulated air is clean and healthy. With filters that capture dust, allergens, and other particles, these units contribute to improved indoor air quality.

Durability is another hallmark of Toshiba's design philosophy. These air conditioners are built with high-quality materials, ensuring long-lasting performance and reliability even in demanding environments. The RAV-SM models are also designed to work efficiently in low outdoor temperatures, extending their usefulness throughout the year.

In summary, the Toshiba RAV-SM1100UT-E and RAV-SM1400UT-E air conditioners represent a fusion of innovation, efficiency, and user-centric design. With their advanced inverter technology, energy efficiency, quiet operation, intelligent controls, and durable construction, they stand as ideal solutions for those seeking effective climate management in their spaces.