Toshiba RAV-SM1100UT-E, RAV-SM1400UT-E service manual Display Section, Operation Section

Page 54

ACCESSORIES

Display Section

All indicators are shown in the right and the lower figures for the explanation.

Only selected contents are display in actual operation.

When turning on the leakage breaker at the first time 3 minutes later, [SET DATA] flashes about for 1 minute on the display part of the remote controller. While this display is flashing, the model is being automatically confirmed. Accordingly, wait for 1 minute after [SET DATA] display has disappeared, and then use the remote controller.

ADR

ADR

SET

CL

ACLSENSOR

Display section

Operation section

Operation Section

Push each button to select a desired operation.

The details of the operation needs to be set up once, afterward, the air conditioner can be

used by pushing button only.

1

5

51

 

 

1

2

 

5

 

6

 

 

3

 

7

 

8

4

ADR

9

 

 

 

 

10

2

3

SET

CL

4

6

ADR

ACL

SENSOR

7

1 Transmitting indication

Displayed while operating the switches of the remote controller.

2 Mode display

The selected operation mode is displayed.

3 Fan mode select display

The selected fan mode is displayed. (AUTO)

(HIGH) (MED.) (LOW)

4 Filter display

If “FILTER ” is displayed, clean the air filter.

5 CHECK display

Displayed while the protective device works or a trouble occurs.

6 Set up temperature display

The selected set up temp. is displayed.

7 Flap position display

8 SWING display

Displayed during up/down movement of the flap.

9 Timer time display

Time of the timer is displayed.

(When a trouble occurs, the check code is displayed.)

10 Timer SETIN setup display

When pushing the Timer SET button, the display of the timer is selected in

order of [OFF] ®

[OFF] repeat OFF timer ® [ON] ® No display.

1 Operation select button Selects desired operation mode.

2 Fan mode select button Selects a fan mode.

3 Timer set button

TIMER SET button is used when the timer is set up.

4 Check button

CHECK button is used for check operation. During normal operation, do not use this button.

5 Temperature set button

Adjusts required room temperature. Set required set temperature by

pushing or .

6 Start/Stop button

When the button is pushed, operation starts, and it stops by pushing the button again.

When the operation stops, the operation lamp and all displays disappear.

7 Filter reset button

Resets (Erases) “FILTER ” display.

OPTION :

Remote controller sensor

Usually the TEMP. sensor of the indoor unit measured a temperature. A temperature around the remote controller can also be measured.

For details, contact the dealer from which you have purchased the air conditioner.

Image 54
Contents Split Type Accessories Adoption of NEW RefrigerantInstallation Manual Way Air Discharge Cassette TypeTo Disconnect the Appliance from Main Power Supply Precautions for SafetyNew Refrigerant Air Conditioner Installation Connect the connecting cable correctlyInappropriate grounding may cause electric shock Accessory and Installation Parts Accessory and RefrigerantSelection of Installation Before installationObstacle at rear side Upper side is free Installation PlaceNecessary Space for Installation Obstacle at front side Upper side is freeSerial installation at front and rear sides Installation of Outdoor UnitStandard installation Obstacles at both front and rear sidesFor Reference Knockout procedureRefrigerant Piping Connection Piping connectionRefrigerant Piping Pipe Forming/End PositioningTightening of Connecting Part RequirementEvacuating Air PurgeVacuum pump How to open the valve How to close the valveSingle phase 50 Hz How to wireStripping length power cord and connecting cable Electrical WorkFinal Installation Checks Check and Test OperationSelf-Diagnosis by LED Indication Changes in the product and components New tools for R410ANew tools for R410A Applicable to R22 model Changes Accessories Sold Separately Precautions for SafetyRAV-SM1100AT-E RAV-SM1400AT-E Parts Name Indoor unitOutdoor unit Parts Name of Remote Controller Display sectionOperation section Preparation Turn on the main power switch and/or the leakage breakerCorrect Usage StopWhen restarting the operation after stop Mode select button ModeTemperature button StartHow to stop swinging How to set up the wind directionHow to start swinging Heat operationTimer Operation Timer operationCancel of timer operation Never open doors and windows more often than necessary Window curtainsGet uniform circulation of room air If you do not plan to use the unit for more than 1 month MaintenanceCleaning of remote controller Checks before operationAIR Conditioner Operations and Performance Troubles and Causes RE-INSTALLATIONDo not install the air conditioner in the following places Be careful with noise or vibrationsInoperative Part name ’ty Shape Separate sold partsPart name ’ty Shape Usage Part namePrecautions for Safety Inappropriate grounding may cause electric shock Avoid installing in the following places Selection of Installation PlaceInstallation space Model RAVHeight list of ceiling possible to be installed Selection of installation place Discharge directionAdvice Ceiling heightSM1100UT-E External viewModel RAV SM1400UT-EInstallation of hanging bolt Installation of ceiling opening and hanging boltInstallation of ceiling panel Sold separately Flexible hose Drain Piping WorkPiping/Heat insulating material Adhesive inhibitedDrain up Connection procedureCheck the draining Perform heat insulatingTightening connection Permissible Piping Length and HeatFlaring dia meter size a Unit mm Tightening torque of flare pipe connectionsGas leak check Use a vacuum pumpOpen the valve fully Thermal insulation processPacked valve handling precautions Valve at gas sideBe sure to connect earth wire. Grounding work Remote controller wiringCable connection Cabling on the ceiling panelWiring diagram Remote Controller CablingCabling diagram CablingProcedure How to execute a test runCase of wired remote controller Test RUNTroubleshooting Confirmation of error historyConfirmation and check Maintenance Accessories ContentsTCB-AX21U W-E 85464189556000Precautions for Safety Remote ControllerName and Operation HOW to SET the FAN Speed Signal Receiving PartDisplay Section Operation SectionHOW to Operate the Unit HOW to Operate the TimerHOW to Adjust AIR Direction Slide SwitchHOW to Insert the Batteries HOW to Handle the Remote Controller HOW to USE the Remote Controller CorrectlyAddress Start HOW to Perform Emergency OperationBefore Asking Repair Work Before asking a repair work, check the following itemsHow to check the program operation time FeaturesTurn on the power supply of the air conditioner RBC-EXW21EName and Operation of Each Part HOW to USE the Timer Correctly When ON/OFF time is set as follows, Error is displayed When push SET Button,Set error Next set up the operation time to the program 2To be checked Clearance of Holiday setupPush DAY button and put the operation Clear of a part of the programMatters to be memorized Power failure Operation of program weekly timer and air conditionerResuming of operation RBC-AS21E Selected mode displays Cooling only type Temperature Setup buttonSelected mode displays Heat pump type Start/Stop button Check button Used in servicingPush either or set to Auto Recommended temperature HOW to Operate AIR ConditionerPower supply Push button Push button to select fan speedInstallation Manual Check after installation Installation of adjust corner capInstallation of suction grille For wireless remote controllerRequirement for installation Multiple remote controllers Accessory partsHow to install remote controller Requirement to install Remote controllerRemote controller test run setup Accessory partsRequirement for installation Multiple remote controllers Installation placeRequirement to install Program weekly timer Accessory parts Part Name ’tyHow to install the program weekly timer Program weekly timer test run setupAccessory parts Requirement to install the remote sensorHow to install the remote sensor Drain-up Kit For Concealed Duct Type Indoor Unit To Personnel Charged in Installation Work and Service Components For Installation ProfessionalsUse for Indoor Unit Only Combination List of Adapter PartsCase of 4-way Ceiling Cassette RAV-SM **0 UT-E Case of Concealed Duct RAV-SM **0 BT-EAddress No. setup table SW01 ProcedureContents Main To Customers

RAV-SM1400UT-E, RAV-SM1100UT-E specifications

Toshiba has consistently been recognized for its commitment to innovation and quality in the HVAC market, and the RAV-SM1100UT-E and RAV-SM1400UT-E models exemplify this dedication. These inverter air conditioners are designed to provide efficient cooling and heating solutions for diverse applications, ensuring comfort in both residential and commercial spaces.

One of the standout features of the RAV-SM1100UT-E and RAV-SM1400UT-E is their advanced inverter technology. This technology allows the units to adjust their cooling and heating capacities based on the real-time conditions, leading to significant energy savings compared to traditional fixed-speed systems. The inverter allows for smooth operation at varying speeds, reducing energy consumption while maintaining a consistent indoor climate.

Both models offer exceptional efficiency ratings. With a high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER), these units are designed to operate sustainably while delivering powerful performance. The RAV-SM1100UT-E offers a cooling capacity of 11 kW, while the RAV-SM1400UT-E boasts a more robust 14 kW, making them suitable for a range of spaces from smaller offices to larger commercial properties.

Another significant characteristic is their quiet operation. Toshiba has engineered these units to minimize noise levels, ensuring a tranquil environment. This is particularly beneficial in settings like hotels, restaurants, and workplaces where noise can be disruptive.

The RAV-SM series is also equipped with intelligent control technology. This feature allows users to manage the system from anywhere using a smartphone app, providing convenience and flexibility. Integration with smart home systems further enhances usability, making it easy to program schedules and adjust settings remotely.

Additionally, both models employ a variety of robust filtration systems, ensuring that the circulated air is clean and healthy. With filters that capture dust, allergens, and other particles, these units contribute to improved indoor air quality.

Durability is another hallmark of Toshiba's design philosophy. These air conditioners are built with high-quality materials, ensuring long-lasting performance and reliability even in demanding environments. The RAV-SM models are also designed to work efficiently in low outdoor temperatures, extending their usefulness throughout the year.

In summary, the Toshiba RAV-SM1100UT-E and RAV-SM1400UT-E air conditioners represent a fusion of innovation, efficiency, and user-centric design. With their advanced inverter technology, energy efficiency, quiet operation, intelligent controls, and durable construction, they stand as ideal solutions for those seeking effective climate management in their spaces.