PRODUCT NOMENCLATURE
3-5 Ton Sunline Magnum™ Model Number Nomenclature
D Y 048 N04 A 2 A AA 2 0 1 2 4 A
Product Category
D = A/C, Single Pkg.,
Product Identifier
Y = 14.0 SEER
Nominal Cooling Capacity
036 = 3.0 Ton
048 = 4.0 Ton
060 = 5.0 Ton
Heat Type and Nominal Heat Capacity
C00 = Cooling Only. Suitable for Field
Installed Electric Heat
Gas Heat Options
N04 = 40 MBH Output Aluminized Steel, 1 Stage (036) N06 = 60 MBH Output Aluminized Steel, 1 Stage (048) N08 = 80 MBH Output Aluminized Steel, 1 Stage
(036, 060)
N10 = 100 MBH Output Aluminized Steel, 1 Stage (048, 060)
D06 = 60 MBH Output Aluminized Steel, 2 Stage (036, 048, 060)
D10 = 100 MBH Output Aluminized Steel, 2 Stage (036*, 048, 060)
S04 = 40 MBH Output Stainless Steel, 1 Stage (036) S06 = 60 MBH Output Stainless Steel, 1 Stage (048) S08 = 80 MBH Output Stainless Steel, 1 Stage
(036, 060)
S10 = 100 MBH Output Stainless Steel, 1 Stage (048, 060)
T06 = 60 MBH Output Stainless Steel, 2 Stage (036, 048, 060)
T10 = 100 MBH Output Stainless Steel, 2 Stage (036*, 048, 060)
Electric Heat Options
E05 = 5 KW
E07 = 7 KW
E10 = 10 KW
E15 = 15 KW
E20 = 20 KW
E30 = 30 KW
*(D, T)10 = 92 MBH Output on 036 Models
Airflow
A = Direct Drive
B = Direct Drive/Single Input Economizer
D = Direct Drive/Motorized Damper
Voltage
1 =
2 =
4 =
5 =
Product Style
A = Style A
Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
SS Drain Pan
CPC Controller, DFS, APS
Johnson Controller, DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity IntelliComfort Controller
Simplicity IntelliComfort Controller w/ModLinc
2" Pleated filters
BAS Ready Economizer
Any Combination of Additional Options that Don’t Have an Option Code
Product Generation
2 = Second Generation
Additional Options | |
|
|
Standard Cabinet | Hinged Filter Door & Toolless Access Cabinet |
|
|
AA = None | BA = Hinged Filter Door & Toolless Access Panels |
AB = Phase Monitor | BB = Phase Monitor, Hinged Filter Door & Toolless |
AC = Coil Guard | Access Panels |
AD = Dirty Filter Switch | BC = Coil Guard, Hinged Filter Door & Toolless |
AE = Phase Monitor & Coil Guard | Access Panels |
AF = Phase Monitor & Dirty Filter Switch | BD = Dirty Filter Switch, Hinged Filter Door & |
AG = Coil Guard & Dirty Filter Switch | Toolless Access Panels |
AH = Phase Monitor, Coil Guard & Dirty Filter Switch | BE = Phase Monitor & Coil Guard, Hinged Filter |
AS = Bottom Drain Connection | Door & Toolless Access Panels |
RC = Coil Guard & American Flag | BF = Phase Monitor & Dirty Filter Switch, Hinged |
TA = Technicoat Condenser Coil | Filter Door & Toolless Access Panels |
TJ = Technicoat Evaporator Coil | BG = Coil Guard & Dirty Filter Switch, Hinged Filter |
TS = Technicoat Evaporator and Condenser Coil | Door & Toolless Access Panels |
| BH = Phase Monitor, Coil Guard & Dirty Filter Switch, |
| Hinged Filter Door & Toolless Access Panels |
|
|
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits
Installation Options
A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
Options
1 = Disconnect
2=
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Johnson Controls Unitary Products | 3 |