York DY 048, DY 060 warranty FIELD-INSTALLED Accessories

Page 7

343615-YTG-B-0308

Factory installed Smoke Detectors in the Return Air, may be subjected to freezing temperatures during "off" times due to Out Side Air infiltration. These Smoke Detectors have an operational limit of 32°F to 131°F. Smoke Detectors installed in areas that could be out side those limitations will have to be moved to prevent having false alarms.

STAINLESS STEEL HEAT EXCHANGER - For applica- tions in corrosive environments, this option provides a full stainless steel heat exchanger assembly.

STAINLESS STEEL DRAIN PAN - An optional rust- proof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environ- ments.

BOTTOM DRAIN CONNECTION - An optional bottom drain connection is available for inside the curb connec- tions for applications in cold environments to reduce freezing drain lines.

PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of- phase condition.

DIRTY FILTER SWITCH - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory.

HINGED FILTER DOOR/“TOOLLESS” BLOWER AND ACCESS PANELS (not hinged) - This option allows for easy access and maintenance.

NOTE:Knobs are shipped inside the unit to prevent ship- ping damage. These must be field installed for tool-less operation.

FIELD-INSTALLED ACCESSORIES

SINGLE INPUT ELECTRONIC ENTHALPY ECONO- MIZERS - Includes a slide-in /plug-in damper assembly with fully modulating spring-return motor actuator capa- ble of introducing up to 100% outdoor air with nominal 1% leakage type dampers.

The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling.

The rainhood is painted to match the basic unit and must be field-assembled before installing.

MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in /plug-in damper assembly with a 2- position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down.

The rain hood is painted to match the basic unit and must be field assembled before installing.

ELECTRIC HEATERS wired for single point power sup- ply. These nickel chromium heater elements are pro- vided with limit and automatic reset capability to prevent operation at excessive temperatures.

ROOF CURBS - Eight and fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly.

Roof curbs are designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports.

HIGH ALTITUDE NATURAL GAS - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet.

PROPANE - Burner orifices, pilot orifices and gas valve parts are provided to convert a natural gas furnace to propane.

HIGH ALTITUDE PROPANE - Burner orifices and pilot orifices are provided for proper furnace operation at alti- tudes up to 6,000 feet. This accessory supplements the basic propane conversion kit.

LOW NOX KIT - Required to reduce the emission of nitrogen oxides below 40 nano grams per joule.

POWER EXHAUST - Our single input economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the condi- tioned space from being over-pressurized during econo- mizer operation.

The power exhaust option can only be used on bot- tom duct configurations.

BAROMETRIC RELIEF DAMPER - This damper acces- sory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct.

Johnson Controls Unitary Products

7

Image 7
Contents Description WarrantyTable of Contents Ton Sunline Magnum Model Number Nomenclature Product NomenclatureFeatures Unit Cutaway FACTORY-INSTALLED Options FIELD-INSTALLED Accessories GAS Heat RATINGS1 Capacity Ratings ARI 210/2401Stage GAS Heat Ratings Horizontal Ducted Inlet ConfigurationVertical Ducted Inlet DY048 / 4 Ton 791 794 1084 1095 DY060 / 5 Ton Vertical Ducted Inlet MBH DY036 Cooling Capacities 3 TONDY048 Cooling Capacities 4 TON 1500 DY060 Cooling Capacities 5 TONMED Electric Heat CFM Limitations Static ResistancesMCA MCA1 YTG-B-0308 YTG-B-0308 Electric Heat Correction Factors DY Physical DataVoltage LIMITATIONS1 Typical Power Wiring Unit Dimensions 3 5 TON COOLING/GAS Heat Front View Detail a Minimum Clearances Unit Dimensions Rear ViewTypical Applications Unit Total Center of GravityRoof Curb Dimensions Operating Weights LBSUnit Cabinet Guide SpecificationsIndoor Evaporator FAN Assembly Outdoor Condenser FAN AssemblyElectric Heating Section Unit Operating CharacteristicsUnit Controls GAS Heating Section Single or 2 StageElectric Heaters Other PRE-ENGINEERED Accessories AvailableManual Outdoor AIR Damper YTG-B-0308 Johnson Controls Unitary Products Johnson Controls Unitary Products York Drive Norman, OK