York DY 060, DY 048 warranty Center of Gravity, Unit Total

Page 30

447/8A

343615-YTG-B-0308

BACK OF UNIT

A

BACK OF UNIT

447/

 

 

8

 

821/

4

 

821/

4

D

 

F

B

 

X

 

X

 

 

 

B

E

 

C

APPROXIMATE

CENTER OF GRAVITY

 

C

FRONT OF UNIT

Y

APPROXIMATE

CENTER OF GRAVITY

CONDENSER COIL

D

END OF UNIT

Y

FRONT OF UNIT

CONDENSER COIL

END OF UNIT

FIGURE 10 -FOUR AND SIX POINT LOADING

TABLE 30: DY 4 AND 6 POINT LOADS WEIGHT DISTRIBUTION

UNIT

TOTAL

 

4-Point Loading (lb)

 

 

 

6-Point Loading (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

 

D

A

B

 

C

D

 

E

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DY036 Cooling/ Electric

575

132

 

125

155

 

164

89

85

 

82

102

 

106

110

DY036N04

615

141

 

133

166

 

175

95

91

 

88

110

 

114

118

DY036D06

625

143

 

135

168

 

178

96

93

 

89

111

 

115

120

DY036N08

635

145

 

138

171

 

181

98

94

 

91

113

 

117

122

DY036D10

645

148

 

140

174

 

184

99

96

 

92

115

 

119

124

DY048 Cooling/ Electric

585

134

 

127

158

 

167

90

87

 

84

104

 

108

112

DY048(D,N)06

635

145

 

138

171

 

181

98

94

 

91

113

 

117

122

DY048(D,N)10

655

150

 

142

177

 

187

101

97

 

94

117

 

121

125

DY060 Cooling/ Electric

590

135

 

128

159

 

168

91

88

 

84

105

 

109

113

DY060D06

640

147

 

139

173

 

182

99

95

 

92

114

 

118

123

DY060N08

650

149

 

141

175

 

185

100

97

 

93

116

 

120

125

DY060(D,N)10

660

151

 

143

178

 

188

102

98

 

95

118

 

122

126

TABLE 31: CENTER OF GRAVITY

DIMENSION

3 - 5 TON

 

 

X

40”

 

 

Y

20”

 

 

30

Johnson Controls Unitary Products

Image 30
Contents Warranty DescriptionTable of Contents Product Nomenclature Ton Sunline Magnum Model Number NomenclatureFeatures Unit Cutaway FACTORY-INSTALLED Options FIELD-INSTALLED Accessories Capacity Ratings ARI 210/2401 GAS Heat RATINGS1Stage GAS Heat Ratings Configuration Horizontal Ducted InletVertical Ducted Inlet DY048 / 4 Ton 791 794 1084 1095 DY060 / 5 Ton Vertical Ducted Inlet DY036 Cooling Capacities 3 TON MBHDY048 Cooling Capacities 4 TON DY060 Cooling Capacities 5 TON 1500MED Static Resistances Electric Heat CFM LimitationsMCA MCA1 YTG-B-0308 YTG-B-0308 DY Physical Data Electric Heat Correction FactorsVoltage LIMITATIONS1 Typical Power Wiring Unit Dimensions 3 5 TON COOLING/GAS Heat Front View Detail a Unit Dimensions Rear View Minimum ClearancesTypical Applications Center of Gravity Unit TotalOperating Weights LBS Roof Curb DimensionsOutdoor Condenser FAN Assembly Guide SpecificationsIndoor Evaporator FAN Assembly Unit CabinetGAS Heating Section Single or 2 Stage Unit Operating CharacteristicsUnit Controls Electric Heating SectionOther PRE-ENGINEERED Accessories Available Electric HeatersManual Outdoor AIR Damper YTG-B-0308 Johnson Controls Unitary Products Johnson Controls Unitary Products York Drive Norman, OK