HP BladeSystem Enclosure technologies manual Several port types are referenced in Figures 12 and

Page 14
Several port types are referenced in Figures 12 and 13:

Figure 11. HP BladeSystem c3000 interconnect bay numbering

For interconnect bay mapping purposes, it does not matter in which device bay a server blade is installed. The mezzanine connectors always connect to the same interconnect bays. Because the connections between the device bays and the interconnect bays are hard-wired through the signal midplane, the server mezzanine cards must be matched to the appropriate type of interconnect module. For example, a Fibre Channel mezzanine card must be placed in the mezzanine connector that connects to an interconnect bay holding a Fibre Channel switch.

Embedded NICs and adapters installed in Mezzanine 1 are supported by single-wide interconnects in interconnect bays 1 and 2 respectively. Mezzanine 2 and 3 can be supported by either single-wide or double-wide interconnects such as InfiniBand or 10 Gb Ethernet devices in interconnect bays 3 and

4.To simplify the installation of the various mezzanine cards and interconnect modules, the Onboard Administrator uses an electronic keying process to detect any mismatch between the mezzanine cards and the interconnect modules.

An internal connection on the midplane between interconnect bays 1 and 2 and an additional connection between interconnect bays 3 and 4 provide an internal link for use as a crosslink port between interconnect bays 1 and 2 or interconnect bays 3 and 4. NIC teaming can be configured between embedded NICs and Mezzanine 1 NICs using the internal crosslinks between the switches through this internal connection.

Several port types are referenced in Figures 12 and 13:

Examples of 1x ports are 1-Gb Ethernet (1-GbE) pass-thru modules and Fibre Channel interconnect modules.

An example of a 2x port is a SAS interconnect module.

Examples of 4x ports are 10-GbE pass-thru modules and InfiniBand interconnect modules.

A full-height server blade plugs into two device bay connectors and has 32 lanes available to the 4 interconnect bays (16 lanes x 2x in Figure 12). Interconnect bay 1 is reserved for Ethernet interconnects. It connects embedded Ethernet NICs to the internal facing ports on the Ethernet

14

Image 14
Contents HP BladeSystem c3000 Enclosure technologies technology briefAbstract Overview of HP BladeSystem c3000 EnclosurePage HP Thermal Logic technologies Active Cool fans HP PARSEC architecture Figure 4. HP BladeSystem c3000 self-sealing enclosureThermal Logic for the server blade and enclosure Power supplies and enclosure power subsystem HP BladeSystem Power Sizer Pooled power Connecting with no power redundancy configured Interconnect options and infrastructure Figure 9. Diagram of the HP BladeSystem c3000 signal midplaneFabric connectivity and port mapping Several port types are referenced in Figures 12 and Mezzanine 1 and Interconnect Bay Virtual Connect Onboard Administrator Enclosure-based DVD ROMPage Insight Display Web GUI Command-line interfaceOnboard Administrator cabling Enclosure link cablingRecommendations SummaryAppendix A. Acronyms in text The following acronyms are used in the text of this documentAppendix B. Fan, power supply, and device bay population guidelines Power supply bays used Table B-1. Power supply placementNumber of power supplies All power supply bays filledPage 8 half-height server blades with both full-height dividers installed Page For additional information, refer to the resources listed below For more informationCall to action Send comments about this paper to TechCom@HP.com