HP BladeSystem Enclosure technologies manual Mezzanine 1 and Interconnect Bay

Page 15
•Mezzanine 1 and Interconnect Bay 2

interconnect. Depending on the configuration requirements, additional mezzanine cards and interconnects can be populated in:

Mezzanine 1 and Interconnect Bay 2

Mezzanine 2 and Interconnect Bays 3 and 4

Mezzanine 3 and Interconnect Bays 3 and 4

The full-height server blade has four embedded NICs and can accept up to three additional mezzanine cards. Each embedded NIC and optional mezzanine port is mapped through the signal midplane to specific ports on interconnect bays. A full-height server blade installed in device bay 1 would have NICs mapped in the following manner:

NIC 1 (PXE default) — Interconnect bay 1 port 5

NIC 2 — Interconnect bay 1 port 13

NIC 3 — Interconnect bay 1 port 1

NIC 4 — Interconnect bay 1 port 9

Figure 12. Port mapping for HP BladeSystem c3000 full-height server blades to interconnect bays

Half-height server blades connect to a single power and signal connector on the signal midplane. The remaining signal connector is allocated to the adjacent device bay (that is, device bays 1 and 5). As a result, half-height server blades do not support four-port mezzanine cards on connector 1, and they do not contain a Mezzanine 3 connector. The extra lanes on the signal midplane are allocated to the adjacent device bay. A four-port PCIe x8 mezzanine card installed in connector 2 PCIe x8 can send x2 signals to interconnect bays 3 and 4.

15

Image 15
Contents technology brief HP BladeSystem c3000 Enclosure technologiesOverview of HP BladeSystem c3000 Enclosure AbstractPage HP Thermal Logic technologies Active Cool fans Figure 4. HP BladeSystem c3000 self-sealing enclosure HP PARSEC architectureThermal Logic for the server blade and enclosure Power supplies and enclosure power subsystem HP BladeSystem Power Sizer Pooled power Connecting with no power redundancy configured Figure 9. Diagram of the HP BladeSystem c3000 signal midplane Interconnect options and infrastructureFabric connectivity and port mapping Several port types are referenced in Figures 12 and Mezzanine 1 and Interconnect Bay Virtual Connect Enclosure-based DVD ROM Onboard AdministratorPage Insight Display Enclosure link cabling Command-line interfaceOnboard Administrator cabling Web GUISummary RecommendationsThe following acronyms are used in the text of this document Appendix A. Acronyms in textAppendix B. Fan, power supply, and device bay population guidelines All power supply bays filled Table B-1. Power supply placementNumber of power supplies Power supply bays usedPage 8 half-height server blades with both full-height dividers installed Page Send comments about this paper to TechCom@HP.com For more informationCall to action For additional information, refer to the resources listed below